Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR 2 ST

نویسندگان

  • Peter J. Quigley
  • Victor S. Behar
چکیده

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between two inflations by standard angioplasty catheters. Chest pain score, 12-lead electrocardiogram, heart rate, and mean aortic pressure were recorded before each inflation and at 1-minute intervals after inflation. Inflation duration during autoperfusion angioplasty (513+± 303 seconds) was longer than for the pre(107+±-55 seconds, p=0.0004) and post(139+± 71 seconds, p=0.0006) standard dilatations. The maximum ST-segment elevation and depression in any lead during autoperfusion angioplasty (0.3 0.5 and 0.6 0.8 mm) was significantly less than for the pre(2.4± 1.7 mm, p=0.002 and 2.2± 1.3 mm, p=0.0004) or post(1.9 + 1.3 mm, p= 0.002 and 1.6±+1.3 mm, p= 0.018) standard dilatations at the same point in time. Maximal chest pain score during autoperfusion (3.2-+ 3.5) was lower than for the pre(6.1 2. 1, p=0.003) but not the post(5.2 3.1, p=0.07) standard angioplasty. All 11 patients underwent successful, uncomplicated procedures. We conclude that this autoperfusion catheter significantly reduces ischemic symptoms and signs during coronary angioplasty, allowing prolonged periods of balloon inflation. (Circulation 1988;78:1128-1134)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...

متن کامل

Preservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.

A newly designed balloon coronary angioplasty catheter that allows passive antegrade blood flow during balloon inflation (autoperfusion catheter) was compared with a standard balloon coronary angioplasty catheter. In a randomized sequence, inflations were performed for 3 min in the left circumflex coronary artery of 12 dogs with the standard catheter followed by the autoperfusion catheter or vi...

متن کامل

Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.

An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...

متن کامل

Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty.

Electrocardiographic manifestations of transient myocardial ischemia were studied, in 11 patients undergoing angioplasty (PTCA) of a left anterior descending coronary artery stenosis, by the visual inspection of the standard surface electrocardiogram (S-ECG) and the intracoronary ECG (IC-ECG) as well as computer-assisted analysis of the S-ECG. Cross-correlation analysis (CCA) performed by compu...

متن کامل

Value of the bipolar lead CM5 in electrocardiography.

Only bipolar lead recording are available during ambulatory monitoring. Their sensitivity in detecting ST segment changes in relation to standard electrocardiographic leads is not known. The magnitude and direction of ST segment changes in the bipolar lead CM5 were compared with those in standard electrocardiographic leads in patients during exercise testing and percutaneous transluminal corona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005