Effects of ECCS on the Cold-Leg Fluid Temperature during SGTR Accidents
نویسنده
چکیده
The LSTF experiment simulating the SGTR accident at the Mihama Unit-2 reactor is analyzed using the RELAP5/MOD3.3 code. In the accident, and thus in the experiment, the ECC water was injected not only into the cold legs but into the upper plenum. Overall transients during the experiment such as pressures and fluid temperatures are simulated well by the code. The cold-leg fluid temperatures are shown to decrease if the upper plenum injection system is connected to the cold leg. It is found that the cold-leg fluid temperatures also decrease if the upper-plenum injection is not used and the cold-leg injection alone is actuated. Keywords—SGTR, LSTF, RELAP5, ECCS.
منابع مشابه
Fluent Analysis of a Rosa Cold Leg Stratification Test
One of the OECD ROSA project tests, investigating temperature stratification in the cold legs and the downcomer during ECCS water injection under single-phase natural circulation conditions was analysed with the FLUENT code. The guidance given in the „Best Practice Guidelines for the Use of CFD in Nuclear Reactor Safety Applications” of the OECD GAMA group was followed. Steady-state calculation...
متن کاملEvaluation of Thyroid Hormones, Blood Gases, Body Antioxidant Status, the Activity of Blood Enzymes and Bone Characteristics in Broiler Chickens with Cold Induced Ascites
A total of 150 day old female chickens (Ross 308) were randomly allocated to 2 groups with 5 replicate and 15 chicks in each replicate to determine the effects of cold induced ascites on performance, antioxidant status, blood enzyme activities and bone metabolism. The two experimental treatments were: 1) chicks that reared under normal temperature (NT) and 2) chicks that reared under cold tempe...
متن کاملA model for enhanced heat transfer in an enclosure using Nano-aerosols
In this study, the behavior of nanoparticles using a numerical model is discussed. For this study a model for the expansion in free convection heat transfer and mix in a rectangular container with dimensions of 1 × 4 cm using Nano-aerosols in the air is going when copper nanoparticles, use and by changing the temperature difference between hot and cold wall, we will examine its impact on the ra...
متن کاملThermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers
Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. The...
متن کاملNumerical investigation on Effect of thermally isolated piston on improving SI engine performance during the cold start conditions
In low ambient temperatures the engine will have poor output torque and power generation at the first cycles of its performance, long start time and huge noxious emissions because of insufficient temperature and quality of air-fuel mixture and failure of flame to burn the charge. It is noted that any attempt to increase the charge temperature leads to better combustion conditions. By applying t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015