Experimental Implementation of Smart Glove Incorporating Piezoelectric Actuator for Hand Tremor Control

نویسنده

  • M. MAILAH
چکیده

This paper examines the effectiveness of a glove specifically designed to compensate human hand tremor by incorporating a type of piezoelectric actuator. In this paper, the experimental results are divided into two parts involving actual human hand tremor and model hand-arm tremor. Both experiments were done using same measurement equipments, experimental setup and programming to evaluate the effectiveness of the glove in reducing the hand tremor. The initial experiment was done by measuring human hand tremor to determine the coherence frequency while other was performed on a hand-arm model with artificial vibration exciter to validate the response of the actual hand tremor. A number of selected sample frequencies were chosen for the experiment. Next, a piezoelectric actuator was employed as the main active element for the compensation of the tremors in both systems. The results presented both in time and frequency domains show that most tremors are readily suppressed to demonstrate the effectiveness of the proposed systems. They are considered as useful data that can be used for further investigation into the technique of effective human hand tremor suppression, particularly applicable to patients suffering from uncontrollable shaking or trembling such as in Parkinson’s disease, white hand syndrome, etc. Subsequently, the output of this investigation can be also used to assist in developing advanced control strategies that involve the generation of controlled signals as the input for the piezoelectric actuator or other similar device to suppress the hand tremor. The presented system is notable for simplicity and low cost. Key-words: Human hand tremor, Smart glove, Piezoelectric Actuator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Buckling Analysis of FG Plate with Smart Sensor/Actuator

In this paper, the active buckling control of smart functionally graded (FG) plates using piezoelectric sensor/actuator patches is studied. A simply supported FG rectangular plate which is bonded with piezoelectric rectangular patches on the top and/or the bottom surface(s) as actuators/sensors is considered. When a constant electric charge is imposed, the governing differential equations of mo...

متن کامل

Active Control method for Postural Tremor via Iterative Learning Algorithm

This paper presents the behavior and the effective way to suppress the human hand postural tremor using the active force control method. The main advantages of proposed method include; its simple control technique, practically applicable in real-time due to the much lesser computational burden and the extra robustness feature the method generates. The actual tremor data from a Parkinson disease...

متن کامل

Suppression of Hand Postural Tremor Via Active Force Control Method

This paper presents the behavior and the effective way to suppress the human hand postural tremor using the active force control method. The main advantages of proposed method include; its simple control technique, practically applicable in real-time due to the much lesser computational burden and the extra robustness feature the method generates. The actual tremor data from a Parkinson disease...

متن کامل

H∞ control for a smart micro-positioning system with an analytical model for the output of the inverse compensation

An experimental study was carried out on a piezoelectric actuator in order to explore the benefits of a mathematical formula [1], that describes the output of the inverse compensation when an inverse Prandtl-Ishlinskii hysteresis model is applied as a feedforward compensator. The inverse Prandtl-Ishlinskii was first formulated and applied for compensation of hysteresis nonlinearities of a piezo...

متن کامل

Sensing and Cancellation of Tremors in Surgeon’s Hands during Microsurgery

Physiological tremors reduce the precision of surgeons during microsurgery. Active cancellation of tremor will improve the results of microsurgery. It will also lead to the development of more sophisticated surgical procedures, previously considered difficult to perform. Tele-robotic systems, steady-hand robot and Micron active hand-held instrument are currently existing techniques for tremor c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010