Areas of breast tissue covered in cone beam breast CT imaging
نویسندگان
چکیده
The value of cone beam breast computed tomography (CBBCT) imaging on covered areas of breast tissue, which is the relation between imaging quality and CT dose were studied. Multi-energy spectrum was used to radiate same-size built-in calcifications and lump breast motifs under the condition of the same number of particles by utilizing the Monte Carlo-based GATE simulation software; breast motif images were restructured by using FBP restructuration algorithm to gain the distribution of radiation dose in the breast motif; radiation dose was calculated and signal-to-noise ratio (SNR) to define how quality factor M and dose efficiency η reflect the relations between radiation dose and imaging quality. Based on the comparison of the calcification number, diameter, and the diameter of tumor among head side, foot side, inner side, outer side and rear side, the difference was meaningless in terms of statistics. Based on the comparison between SNR and contrast-to-noise ratio and between dose efficiency η and quality factor M in different areas, the difference was not statistically significant. In conclusion, the imaging quality of CBBCT was good in the head, foot, inner, outer and rear sides of breast, with acceptable CT dose.
منابع مشابه
Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images
The use of mammography techniques for the screening and diagnosis of breast cancers has been limited by the overlapping of cancer symptoms with normal tissue structures. To overcome this problem, two methods have been developed and actively investigated recently: digital tomosynthesis mammography and cone beam breast CT. Comparison study with these three techniques will be helpful to understand...
متن کاملCircle plus Partial Helical Scan Scheme for a Flat Panel Detector-Based Cone Beam Breast X-Ray CT
Flat panel detector-based cone beam breast CT (CBBCT) can provide 3D image of the scanned breast with 3D isotropic spatial resolution, overcoming the disadvantage of the structure superimposition associated with X-ray projection mammography. It is very difficult for Mammography to detect a small carcinoma (a few millimeters in size) when the tumor is occult or in dense breast. CBBCT featured wi...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملImage guidance during breast radiotherapy: a phantom dosimetry and radiation-induced second cancer risk study
Imaging procedures utilised for patient position verification during breast radiotherapy can add a considerable dose to organs surrounding the target volume on top of therapeutic scatter dose. This study investigated the dose from a breast kilovoltage cone-beam CT (kV-CBCT), a breast megavoltage fan-beam CT (MV-FBCT), and a TomoDirect breast treatment. Thermoluminescent dosimeters placed within...
متن کاملAssessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters
OBJECTIVE To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. MATERIALS AND METHODS Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols a...
متن کامل