Should women receive left ventricular assist device support?: findings from INTERMACS.

نویسندگان

  • Eileen M Hsich
  • David C Naftel
  • Susan L Myers
  • Eiran Z Gorodeski
  • Kathleen L Grady
  • Darlene Schmuhl
  • Karen L Ulisney
  • James B Young
چکیده

BACKGROUND Small studies have reported women to have worse outcomes and more adverse events after implantation of mechanical circulatory support device compared with men. To further evaluate sex differences in outcome, we used the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). METHODS AND RESULTS There were 401 women (pulsatile devices=78) and 1535 men (pulsatile devices=402) from 89 institutions who were prospectively enrolled into the INTERMACS database for primary implantation of a left ventricular assist device (LVAD) between June 23, 2006, and March 31, 2010. Extensive preimplantation and outcome data were collected on all patients. With a mean follow-up of 7 months, 67 females (17%) died and 250 males (16%) died. There was no statistically significant sex difference in mortality for either pulsatile-flow (P=0.82) or continuous-flow (P=0.95) devices in adjusted and unadjusted models. There were also no statistically significant sex differences with time to first infection, bleeding, or device malfunction. However, female sex was associated with an increased hazard of first neurological event (adjusted hazard ratio, 1.44; 95% CI, 1.05-1.96; P=0.020). CONCLUSIONS There were no significant sex differences in mortality, time to first infection, bleeding, or device malfunction with either pulsatile- or continuous-flow LVADs. However, women had an increased risk of first neurological event. For urgent/emergent mechanical support, the benefit of LVAD support likely outweighs the risk, but it remains less clear for women undergoing elective LVAD implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracorporeal life support prior to left ventricular assist device implantation leads to improvement of the patients INTERMACS levels and outcome

BACKGROUND The objective of this study was to evaluate the outcome of left ventricular assist device (LVAD) implantation after initial extracorporeal life support (ECLS) in patients with cardiogenic shock and the incidence of post implantation right ventricular failure. METHODS & RESULTS All patients on ECLS therapy for cardiogenic shock prior to LVAD implantation (n = 15) between October 201...

متن کامل

INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) Profiling Identifies Ambulatory Patients at High Risk on Medical Therapy After Hospitalizations for Heart Failure.

BACKGROUND INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profiles provide important prognostic information for patients with advanced heart failure (HF) receiving mechanical support. The value of INTERMACS profiling has not been shown for patients followed on medical therapy for advanced HF at centers that also offer mechanical circulatory support. METHODS AND...

متن کامل

Myocardial Recovery in Patients Receiving Contemporary Left Ventricular Assist Devices: Results From the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS).

BACKGROUND Time course and predictors of myocardial recovery on contemporary left ventricular assist device support are poorly defined because of limited number of recovery patients at any implanting center. This study sought to investigate myocardial recovery using multicenter data from the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). METHODS AND RESULTS Th...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Ventricular Assist Device in Acute Myocardial Infarction.

BACKGROUND Patients with acute myocardial infarction (AMI) complicated by acute heart failure or cardiogenic shock have high mortality with conventional management. OBJECTIVES This study evaluated outcomes of patients with AMI who received durable ventricular assist devices (VAD). METHODS Patients in the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) registry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2012