Magnetic Resonance Monitoring of Histological Organization Processes in the Excluded Aneurysm
نویسندگان
چکیده
Background—The purpose of the present study was to systematically analyze the histopathologic organization processes in excluded aneurysms after endovascular stenting and to develop a noninvasive monitoring method for these processes using MRI. Methods and Results—In 36 mongrel dogs, autologous aortic aneurysms were created. Endovascular treatment was performed using covered stents. Follow-up was after 1 week, 6 weeks, and 6 months. MRI was performed with T2-weighted turbo-spin-echo sequences and T1-weighted spin-echo sequences and was repeated after contrast bolus with gadolinium. Histopathologic findings were correlated to signal intensities (SIs) of MRI images. SIs of distinct areas were analyzed and related to the SI of the reference tissue (SI ratio). The histological organization process was gradated in the following 4 classes: class 0, detritus without organization; classes I and II, connective tissue proliferation with increasing fiber synthesis; and class III, dense fibrous connective tissue. The SI ratios of T2-weighted images were significantly reduced from 4.76 in detritus (0) to 1.70 in dense fibrous connective tissue (III) as a function of histopathologic classes. SI ratios of T1-weighted images were reduced from 1.84 (0) to 1.12 (III). Contrast bolus with gadolinium-DTPA showed no change of SI ratio in detritus (0.99) but an increase from 1.12 (I) to 1.70 (III) as organization increased. Conclusions—The histological organization of excluded aneurysms can be monitored by MRI. Progressive organization is indicated by decreasing SIs in T2and an increasing signal increase in T1-weighted images after gadolinium bolus. (Circulation. 2002;105:1995-1999.)
منابع مشابه
Endovascular aneurysm repair: Magnetic resonance monitoring of histological organization processes in the excluded aneurysm.
BACKGROUND The purpose of the present study was to systematically analyze the histopathologic organization processes in excluded aneurysms after endovascular stenting and to develop a noninvasive monitoring method for these processes using MRI. METHODS AND RESULTS In 36 mongrel dogs, autologous aortic aneurysms were created. Endovascular treatment was performed using covered stents. Follow-up...
متن کاملApplication of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کاملUse of Magnetic Resonance Imaging in Food Quality Control: A Review
Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...
متن کاملبررسی فراوانی واریاسیون ها و پاتولوژی های حلقه ویلیس با استفاده Magnetic Resonance Angiogram مغزی بدون تزریق ماده حاجب
Background and purpose: The complexity of anatomical variation of Willis circle (CW) has made it susceptible to variation. The goal of this study was to determine the prevalence of the CW variations using magnetic resonance angiography (MRA) without contrast agent in patients attending Sari Imam Khomeini Hospital. Materials and methods: In a cross-sectional study, 200 subjects referring for ...
متن کاملSize Reproducibility of Gadolinium Oxide Based Nanomagnetic Particles for Cellular Magnetic Resonance Imaging: Effects of Functionalization, Chemisorption and Reaction Conditions
We developed biofunctionalized nanoparticles with magnetic properties by immobalizing diethyle-neglycol (DEG) on Gd2O3, and PEGilation of small particulate gadolinium oxide (SPGO) with two me-thoxy-polyethyleneglycol-silane (mPEG-Silane 550 and 2000 Da) using a new supervised polyol route, described recently. In conjunction to the previous study to achieve a high quality synthesis and increase ...