Improved membrane filtration method incorporating catalase and sodium pyruvate for detection of chlorine-stressed coliform bacteria.
نویسندگان
چکیده
In vitro pure culture studies were conducted on three different strains of Escherichia coli (K-12, EPA 00244, and SWEI) to determine the effect of chlorination on catalase activity. In each case, stationary-phase cells exhibited significant (P less than 0.001) reductions in enzyme activity following exposure to chlorine. Mean differences in activity between control and chlorine-stressed cells ranged from 8.8 to 20.3 U/mg of protein for E. coli SWEI and EPA 00244, respectively. Following initial enzyme studies, resuscitation experiments utilizing the membrane filtration technique were conducted on chlorinated sewage effluent. Five different amendments, including catalase (1,000 U per plate), heat-inactivated catalase (1,000-U per plate), sodium pyruvate (0.05%), a catalase-sodium pyruvate combination (1,500 U/0.01%), and acetic acid (0.05%), were tested for the ability to enhance detection of chlorine-stressed cells on M-fecal coliform (M-FC), mT7, M-Endo, and tryptone-glucose-yeast extract (TGY) media. Significant (P less than 0.001) increases in recovery of fecal coliforms on M-FC, total coliforms on mT7 and M-Endo, and total heterotrophs on TGY were obtained on plates containing catalase, pyruvate, or the combination of these compounds. Supplementation with heat-inactivated catalase and acetic acid did not improve recovery of chlorine-stressed cells compared with recovery on nonamended media. Subsequent analysis of colonies from plates containing compounds which enhanced recovery indicated coliform verification percentages of greater than 80% on M-FC, greater than 90% on mT7, and greater than 94% on M-Endo media. These data suggest that the addition of peroxide-degrading compounds to various standard recovery media may improve detection of both coliform and heterotrophic bacteria in chlorinated waters.
منابع مشابه
Fungi Occurrence Assessment in Drinking Water Distribution Systems and Its Relationship with Fecal Indicator Bacteria
Introduction: As recommended by World Health Organization, consumption of the fungal contaminated water does not cause to serious infection, but may lead to healthy or aesthetic problems. The aim of this research was to assess the occurrence of fungi in water and its relationship with fecal indicator bacteria. Materials and Methods: 110 water samples were collected from different location of w...
متن کاملRadiometric method for the detection of coliform organisms in water.
A new radiometric method for the detection of coliform bacteria in water has been described. The method is based on the release of (14)CO(2) from [(14)C]lactose by bacteria suspended in growth medium and incubated at 37 C. The evolved (14)CO(2) is trapped by hyamine hydroxide and counted in a liquid scintillation spectrometer. The method permits the detection of 1 to 10 organisms within 6 h of ...
متن کاملFecal Coliform Organism Enumeration in Chlorinated Wastewaters
The accepted method for determining disinfection efficiency of wastewater treatment systems is routinely to perform fecal coliform bacteria analyses on the final effluent (5). Standard Methods for the Examination of Water and Wastewater outlines two procedures for fecal coliform analysis: the membrane filtration technique and the most-probable-number (MPN) method (1). For chlorinated effluents,...
متن کاملارزیابی کیفیت باکتریولوژیکی آب تولیدی دستگاههای تصفیه آب خانگی
Background and purpose: Awareness of people about drinking water impurities and the demand for better water quality have led to widespread application of point-of-use (POU) water treatment devices. The aim of this study was to investigate the bacteriological quality of water produced by household water treatment devices. Materials and methods: This cross-sectional descriptive study was perfo...
متن کاملEnumeration and characterization of standard plate count bacteria in chlorinated and raw water supplies.
Nearly 700 standard plate count (SPC) bacteria were isolated from drinking water and untreated surface water and identified according to a scheme developed to permit the rapid, simple classification of microorganisms to genus, species, or group. Actinomycetes and Aeromonas species were the two most common groups of SPC bacteria in chlorinated distribution water. Aeromonas spp. and Enterobacter ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 56 11 شماره
صفحات -
تاریخ انتشار 1990