Myopia control during orthokeratology lens wear in children using a novel study design.

نویسندگان

  • Helen A Swarbrick
  • Ahmed Alharbi
  • Kathleen Watt
  • Edward Lum
  • Pauline Kang
چکیده

PURPOSE To investigate the effect of overnight orthokeratology (OK) contact lens wear on axial length growth in East Asian children with progressive myopia. DESIGN A prospective, randomized, contralateral-eye crossover study conducted over a 1-year period. PARTICIPANTS We enrolled 26 myopic children (age range, 10.8-17.0 years) of East Asian ethnicity. METHODS Subjects were fitted with overnight OK in 1 eye, chosen at random, and conventional rigid gas-permeable (GP) lenses for daytime wear in the contralateral eye. Lenses were worn for 6 months. After a 2-week recovery period without lens wear, lens-eye combinations were reversed and lens wear was continued for a further 6 months, followed by another 2-week recovery period without lens wear. Axial eye length was monitored at baseline and every 3 months using an IOLMaster biometer. Corneal topography (Medmont E300) and objective refraction (Shin-Nippon NVision-K 5001 autorefractor) were also measured to confirm that OK lens wear was efficacious in correcting myopia. MAIN OUTCOME MEASUREMENTS Axial length elongation and myopia progression with OK were compared with conventional daytime rigid contact lens wear. RESULTS After 6 months of lens wear, axial length had increased by 0.04±0.06 mm (mean±standard deviation) in the GP eye (P=0.011) but showed no change (-0.02±0.05 mm) in the OK eye (P=0.888). During the second 6-month phase of lens wear, in the OK eye there was no change from baseline in axial length at 12 months (-0.04±0.08 mm; P=0.218). However, in the GP eye, the 12-month increase in axial length was significant (0.09±0.09 mm; P<0.001). The GP lens-wearing eye showed progressive axial length growth throughout the study. CONCLUSIONS These results provide evidence that, at least in the initial months of lens wear, overnight OK inhibits axial eye growth and myopia progression compared with conventional GP lenses. Apparent shortening of axial length early in OK lens wear may reflect the contribution of OK-induced central corneal thinning, combined with choroidal thickening or recovery due to a reduction or neutralization of the myopiogenic stimulus to eye growth in these myopic children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myopia Control with Orthokeratology Contact Lenses in Spain (MCOS): Study Design and General Baseline Characteristics

PURPOSE: Although previous studies suggest that orthokeratology contact lens wear slows eye growth in children with progressing myopia, some limitations in the methodology employed have become evident. Furthermore, the safety of this modality of visual correction has not been assessed. The study “Myopia Control with Orthokeratology Contact Lenses in Spain” (MCOS) is being conducted to compare a...

متن کامل

The control effect of orthokeratology on axial length elongation in Chinese children with myopia

BACKGROUND To retrospectively compare axial elongation in children with different degrees of myopia wearing spectacles and undergoing ortho-k treatment. METHODS The medical records of 128 patients who were fitted with spectacles or orthokeratology (ortho-k) lenses in our clinic between 2008 and 2009 were reviewed. Ortho-k group comprised 65 subjects and 63 subjects wearing spectacles were inc...

متن کامل

Myopia Control with a Novel Peripheral Gradient Soft Lens and Orthokeratology: A 2-Year Clinical Trial

OBJECTIVE To evaluate the degree of axial elongation with soft radial refractive gradient (SRRG) contact lenses, orthokeratology (OK), and single vision (SV) spectacle lenses (control) during a period of 1 year before treatment and 2 years after treatment. METHODS This was a prospective, longitudinal, nonrandomized study. The study groups consisted of 30, 29, and 41 children, respectively. Th...

متن کامل

Differences between overnight and long-term wear of orthokeratology contact lenses in corneal contour, thickness, and cell density.

PURPOSE To investigate changes in corneal topography and morphology in human eyes wearing orthokeratology (OK) lenses for overnight and over a 5-year period. MATERIALS AND METHODS Fifty-six adults with moderate myopia were assigned to 2 groups based on age matching: 5-year lens wear (n = 26, 51 eyes) and 1-night lens wear (n = 30, 60 eyes). All subjects wore reverse-geometry OK lenses with th...

متن کامل

Good clinical practice in orthokeratology.

Overnight orthokeratology is becoming more and more popular especially in the Asia-Pacific region where the treatment is primarily used for myopic control in young children. Risk of complications in contact lens wear increases during overnight wear and may further increase when the treatment is used on children. The aim of this paper is to provide a comprehensive guideline for practitioners to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 122 3  شماره 

صفحات  -

تاریخ انتشار 2015