Solution for Dead Space Problem in Ranibizumab Syringe System

نویسندگان

  • Sinan Bilgin
  • Ozcan Kayikcioglu
  • Basak Can
  • Fatma Taneli
چکیده

Intravitreal injection of drugs that inhibit the actions of vascular endothelial growth factor bring high economic burden for the health systems. We evaluated the amount of drug volume retained in two different types of syringes with billed and non billed rubber stopper. Difference between two syringe types is 0.037 g. This indicates a significant amount of volume loss due to dead space between syringe and needle. Consequently, a simple change of design of rubber stopper of the plunger as billed form may reduce significant amount of drug loss due to dead space volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Options for reducing HIV transmission related to the dead space in needles and syringes

BACKGROUND When shared by people who inject drugs, needles and syringes with different dead space may affect the probability of HIV and hepatitis C virus (HCV) transmission differently. METHODS We measured dead space in 56 needle and syringe combinations obtained from needle and syringe programs across 17 countries in Europe and Asia. We also calculated the amounts of blood and HIV that would...

متن کامل

A Continuous Plane Model to Machine Layout Problems Considering Pick-Up and Drop-Off Points: An Evolutionary Algorithm

One of the well-known evolutionary algorithms inspired by biological evolution is genetic algorithm (GA) that is employed as a robust and global optimization tool to search for the best or near-optimal solution with the search space. In this paper, this algorithm is used to solve unequalsized machines (or intra-cell) layout problems considering pick-up and drop-off (input/output) points. Such p...

متن کامل

A simple new technique to measure the effective dead space of the face mask with a water volumeter in infants.

Measuring the effective dead space (EDS) of a face mask has been difficult in infants and the appropriate volume being deducted from lung volume measurements has varied between laboratories. This study measured EDS in 16 infants (age range, 5-36 months) who have cystic fibrosis, undergoing lung volume measurement by N2 washout. A thin plastic bladder, whose neck resided in the mask port, was sh...

متن کامل

Survival of Hepatitis C Virus in Syringes Is Dependent on the Design of the Syringe-Needle and Dead Space Volume

BACKGROUND Many people who inject drugs (PWID) use syringes with detachable needles, which have high dead space (HDS). Contaminated HDS blood may substantially contribute to the transmission of HIV, hepatitis C (HCV), and other blood-borne viruses within this population. Newly designed low dead space (LDS) syringe-needle combinations seek to reduce blood-borne virus transmission among PWID. We ...

متن کامل

Factors that influence the characteristics of needles and syringes used by people who inject drugs in Tajikistan

BACKGROUND "Low dead space" syringes with permanently attached needles retain less fluid, blood, and HIV after use than standard "high dead space" syringes. This reduces the probability of HIV transmission if they are shared by people who inject drugs (PWID). The World Health Organization recently recommended that needle and syringe programs (NSP) offer clients low dead space syringes. The succ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014