Drift and Hysteresis Characteristics of Drug Sensors Based on Ruthenium Dioxide Membrane

نویسندگان

  • Yi-Hung Liao
  • Jung-Chuan Chou
چکیده

The drug sensing properties of procaine and berberine drug sensors based on ruthenium dioxide thin film were investigated. Ruthenium dioxide (RuO₂) membrane prepared using a sputtering method was used as substrates for the drug sensors. The procaine and berberine drug sensors were prepared using a drug-sensitive membrane that measured the procaine and berberine concentration in a linear range from 1×10-2 M to 1×10-6 M and from 1×10-2 M to 1×10-7 M, respectively. The drift rates and hyteresis widths of these ruthenium dioxide based drug sensors were also investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication and Characterization of a Ruthenium Nitride Membrane for Electrochemical pH Sensors

The pH sensing and nonideal characteristics of a ruthenium nitride (RuN) sensing membrane pH sensor were investigated. RuN thin films were deposited from a 99.9% ruthenium target on p-type silicon substrates using radio frequency (r.f.) sputtering with N(2) gas. Subsequently, the nanometric structure and surface morphology of RuN thin films were determined. The sensitivity of the RuN sensing me...

متن کامل

Investigation of Sensitivities and Drift Effects of the Arrayed Flexible Chloride Sensor Based on RuO2/GO at Different Temperatures

We investigate the temperature effect on sensing characteristics and drift effect of an arrayed flexible ruthenium dioxide (RuO₂)/graphene oxide (GO) chloride sensor at different solution temperatures between 10 °C and 50 °C. The average sensor sensitivities according to our experimental results were 28.2 ± 1.4 mV/pCl (10 °C), 42.5 ± 2.0 mV/pCl (20 °C), 47.1 ± 1.8 mV/pCl (30 °C), 54.1 ± 2.01 mV...

متن کامل

Novel Electroless Plating of Ruthenium for Fabrication of Palladium-Ruthenium Composite Membrane on PSS Substrate and Its Characterization

This paper focused on a novel method of electroless plating ruthenium (Ru) on solid or porous substrates like porous stainless steel (PSS) discs or ceramic tubes. A novel complexing plating bath of Ru was developed. It is proven that Ru can be deposited directly on these substrates by the bath at a temperature of 328 K and strong alkaline environment. TGA, SEM, EDX and XRD confirmed the success...

متن کامل

Hysteresis and Material Effects of Printed Strain Gauges Embedded in Organic Coatings

This work reports on the hysteresis behavior and an initial baseline drift of printed strain gauges embedded in organic coating layers on sheet steel that we recently introduced. We subsequently investigated the performance over an extended period of time, which revealed interesting and partially unexpected material properties of printed strain gauges made from silver and carbon. Both silverand...

متن کامل

Reliability of Measured Data for pH Sensor Arrays with Fault Diagnosis and Data Fusion Based on LabVIEW

Fault diagnosis (FD) and data fusion (DF) technologies implemented in the LabVIEW program were used for a ruthenium dioxide pH sensor array. The purpose of the fault diagnosis and data fusion technologies is to increase the reliability of measured data. Data fusion is a very useful statistical method used for sensor arrays in many fields. Fault diagnosis is used to avoid sensor faults and to me...