Detection and wavelet analysis of partial discharges using an optical fibre interferometric sensor for high-power transformers
نویسنده
چکیده
The main problem in power transformers is the degradation of the isolation, and partial discharges are a major contribution to this shortcoming. Partial discharges inside mediumand high-power transformers generate ultrasonic pressure waves which are usually detected by using acoustic piezoelectric sensors placed outside the transformers. In this paper we describe an optical fibre interferometric sensor we are developing for the detection and location of partial discharges by measuring inside the power transformers. This non-intrusive optical fibre sensor allows a high level of sensitivity to be achieved for the typical small pressure variations created by partial discharges, specially if compared with the results obtained by acoustic piezoelectric external sensors. We present interferometrically detected levels of partial discharge. These results indicate that the developed optical fibre sensor is able to detect a partial discharge in the range of 103 pC that produces an optical phase shift of about 2 rad with a resolution of 30 pC in charge means. Finally, the wavelet analysis is used to identify the acoustic patterns instead of the more commonly used Fourier analysis. When transforming the measured signal to the frequency domain, the temporal information disappears. But the acoustic signals really contain numerous transitory pieces of information to be considered. By looking at a Fourier-transformed signal it is impossible to state when a particular event took place. The wavelet analysis helps to solve this problem, and some results are presented here to show this.
منابع مشابه
Classification of Acoustic Emission Based Partial Discharge in Oil Pressboard Insulation System Using Wavelet Analysis
Insulation used in transformer is mostly oil pressboard insulation. Insulation failure is one of the major causes of catastrophic failure of transformers. It is established that partial discharges (PD) cause insulation degradation and premature failure of insulation. Online monitoring of PDs can reduce the risk of catastrophic failure of transformers. There are different techniques of partial d...
متن کاملDetection and Position Location of Partial Discharges in Transformers Using Fiber Optic Sensors
Power transformers are one of the most important components in the electrical energy network. Extending transformer life is very economically valuable due to power outage. Therefore the development of instruments to monitor the transformer condition is of great interest. Detection of partial discharges (PDs) in power transformers is an effective diagnostic because it may reveal and quantify an ...
متن کاملAn ultra-sensitive optical MEMS sensor for partial discharge detection
A diaphragm-based interferometric fiber optical microelectromechanical system sensor with high sensitivity is designed and tested for on-line detection of the acoustic waves generated by partial discharges (PD) inside high-voltage power transformers. In principle, the sensor is made according to Fabry Perot interference, which is placed on a micro-machined rectangular silicon membrane as a pres...
متن کاملPartial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply. Partial discharges are a phenomenon that can cause failures in the transformers if not properly monitored. Typically, the monitoring requires high-cost corrective maintenance or even interruptions of the power system. Therefore, the development...
متن کاملA Fiber Optic PD Sensor Using a Balanced Sagnac Interferometer and an EDFA-Based DOP Tunable Fiber Ring Laser
A novel fiber-optic acoustic sensor using an erbium-doped fiber amplifier (EDFA)-based fiber ring laser and a balanced Sagnac interferometer for acoustic sensing of the partial discharge (PD) in power transformers is proposed and demonstrated. As a technical background, an experimental investigation on how the variations of the fiber birefringence affect the sensor performances was carried out,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -