Iterative correction for ‘pile-up’ in single-photon lifetime measurement
نویسنده
چکیده
A novel iterative algorithm is proposed to correct for pulse, or photon, ‘pile-up’ in the measurement of temporal intensity profiles using time-correlated single-photon counting (TCSPC). Despite the existence of correction algorithms since 1968, most TCSPC experiments are operated in a very low photon-count mode to avoid pulse pile-up effects in the data. This is inefficient and time-consuming, but is the preferred mode of operation as the current correction algorithms are only applicable under conditions of constant source pulse energy. The advantage of the proposed algorithm is that it can be operated under conditions of variable pulse energy. The effectiveness of the algorithm on simulated data is demonstrated and compared with that of the existing method. 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Neural Imaging Using Single-Photon Avalanche Diodes
Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...
متن کاملReal-time fluorescence lifetime actuation for cell sorting using a CMOS SPAD silicon photomultiplier.
Time-correlated single photon counting (TCSPC) is a fundamental fluorescence lifetime measurement technique offering high signal to noise ratio (SNR). However, its requirement for complex software algorithms for histogram processing restricts throughput in flow cytometers and prevents on-the-fly sorting of cells. We present a single-point digital silicon photomultiplier (SiPM) detector accompli...
متن کاملEffective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams
Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملNew approach for attenuation correction in SPECT images, using linear optimization
Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002