Circadian variation of sustained ventricular tachycardia in patients with coronary artery disease and implantable cardioverter-defibrillators.
نویسندگان
چکیده
BACKGROUND While previous studies using epidemiological data and ambulatory ECG monitoring have shown peak occurrence of sudden death and nonsustained ventricular tachycardia in the morning, none have examined circadian variation of potentially life-threatening ventricular tachycardia (VT), nor has any study observed circadian behavior of any arrhythmias in individuals followed longitudinally. We used the event memory of multiprogrammable implantable cardioverter-defibrillators to evaluate the circadian pattern of sustained VT over time. METHODS AND RESULTS Data were reviewed from 32 consecutive patients with coronary artery disease and sustained VT who had received the Ventak PRX (CPI, Inc) cardioverter-defibrillator between May 1991 and August 1993 and had experienced at least one episode of VT terminated by their device. Mean follow-up was 14 +/- 7 months. Among the 2558 episodes recorded by the device logs, VT occurrence peaked between 6 AM and noon (P = .007 by ANOVA among four 6-hour time periods). Harmonic regression revealed a morning peak at 9 AM (P < .01). This morning peak occurred in patients with both frequent and infrequent events. Among 21 patients who experienced more than four VT events, 8 (38%) had an AM peak of VT occurrence (> 35% of VT between 6 AM and noon). Neither age, ejection fraction, event frequency, presenting arrhythmia, nor drug therapy distinguished patients who displayed the AM VT peak. CONCLUSIONS In patients with coronary artery disease, sustained VT displays circadian variation with peak frequency in the morning, similar to that for sudden death. Individual patients who display specific patterns of circadian variation over time can be identified using defibrillator logs. Investigation of circadian variation of other phenomena to elucidate mechanisms of VT should focus on these patients.
منابع مشابه
Indications for and long-term survival in patients with automatic implantable cardioverter-defibrillators.
Automatic implantable cardioverter-defibrillators (AICDs) were implanted in 378 men and 95 women, mean age 69 +/- 12 years. At 3.6-year follow up, survival was 76% in patients who had an AICD because of cardiac arrest as a result of ventricular fibrillation or ventricular tachycardia not resulting from a transient or reversible cause; 85% in patients who had an AICD because of spontaneous susta...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملMindfully Mining MUSTT*
In this issue of the Journal the MUSTT (Multicenter Unsustained Tachycardia Trial) investigators (1), extend their post hoc analyses of the original trial. By comparing outcomes of those patients in the EP group (patients discharged on drugs predicted effective by electrophysiologic testing) who received implanted cardioverter defibrillators (ICDs) to those randomized to no antiarrhythmic thera...
متن کاملLong-Term Outcome With Cardioverter-Defibrillator
The automatic implantable cardioverter-defibrillator was implanted in 270 patients because of life-threatening arrhythmias over a 7 year period. There was a history of sustained ventricular tachycardia or fibrillation, or both, in 96% of these patients, 80% had one or more prior cardiac arrests and 78% had coronary artery disease as their underlying diagnosis. The average ejection fraction was ...
متن کاملSurvival in Patients With Automatic Implantable Cardioverter-Defibrillators
Background. Two hundred eighteen patients were evaluated in a two-phase approach (time to first appropriate discharge, survival after discharge) to identify factors that may be related to maximal benefit derived from use of an automatic implantable cardioverter-defibrillator (AICD). Methods and Results. One hundred ninety-seven patients survived implantation ofAICD, with or without concomitant ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 90 1 شماره
صفحات -
تاریخ انتشار 1994