Dynamic effects of positive-pressure ventilation on canine left ventricular pressure-volume relations.
نویسندگان
چکیده
Positive-pressure ventilation (PPV) may affect left ventricular (LV) performance by altering both LV diastolic compliance and pericardial pressure (Ppc). We measured the effect of PPV on LV intraluminal pressure, Ppc, LV volume, and LV cross-sectional area in 17 acute anesthetized dogs. To account for changes in lung volume independent of changes in Ppc and differences in contractility, measures were made during both open- and closed-chest conditions, during closed chest with and without chest wall binding, and after propranolol-induced acute ventricular failure (AVF). Apneic end-systolic pressure-volume relations (ESPVR) were generated by inferior vena caval occlusions. With the open chest, PPV had no effects. With the chest closed, PPV inspiration decreased LV end-diastolic volume (EDV) along its diastolic compliance curve and decreased end-systolic volume (ESV) such that the end-systolic pressure-volume domain was shifted to a point left of the LV ESPVR, even when referenced to Ppc. The decrease in EDV was greater in control than in AVF conditions, whereas the shift of the ESV to the left of the ESPVR was greater with AVF than in control conditions. We conclude that the hemodynamic effects of PPV inspiration are due primarily to changes in intrathoracic pressure and that the inspiration-induced decreases of LV EDV reflect direct effects of intrathoracic pressure on LV filling. The decreases in LV ESV exceed the amount explained solely by a reduction in LV ejection pressure.
منابع مشابه
Early Effectiveness of Noninvasive Positive Pressure Ventilation on Right Ventricular Function in Chronic Obstructive Pulmonary Disease Subjects with Acute Hypercapnic Respiratory Failure
Introduction: Noninvasive positive pressure ventilation (NIPPV) has become an integral tool in the management of acute hypercapnic respiratory failure (AHRF) in chronic obstructive pulmonary disease (COPD). This study was performed to evaluate the early effects of NIPPV on pulmonary artery pressure (PAP), serum N-terminal pro BNP (NT-proBNP), and ventilatory parameters in the COPD patients with...
متن کاملCOMPARISON BETWEEN THE EFFECTS OF 5 PERCENT HYPERTONIC SODIUM CHLORIDE SOLUTION AND 0.9 PERCENT SODIUM CHLORIDE SOLUTION ON LEFT VENTRICUL AR CONTRACTION
Hypertonic saline solution can absorb part of the intracellular fluid volume into the extracellular space. The effects of this solution on the cardiovascular system are increased coronary flow and increased left ventricular contraction, without sympathetic system activation. This study was designed to assess the effects of hypertonic saline solution in open heart surgery and to compare it w...
متن کاملLoad dependency of end-systolic pressure-volume relations in isolated, ejecting canine hearts.
If characteristic muscle properties such as myocardial viscosity and/or shortening deactivation influence left ventricular ejection in the whole heart, the slope of the left ventricular end-systolic pressure-volume relation should be a function of both the contractile state and the loading mode. Thus, the load dependence of the end-systolic pressure-volume relation was examined using isolated, ...
متن کاملThe effects of airway pressure on cardiac function in intact dogs and man.
Ventilation with positive end-expiratory pressure (PEEP) is associated with reduced cardiac output, but the mechanisms involved are controversial. Possible explanations include increased intrathoracic pressure, reflex changes in myocardial inotropism, pulmonary vascular obstruction and abnormal ventricular interaction. Three types of conscious canine preparations were developed to examine simul...
متن کاملChanges in canine left ventricular size and configuration with positive end-expiratory pressure.
Previous studies have shown that left atrial pressure increases when measured relative to pleura! pressure during positive end-expiratory pressure (PEEP). We studied the factors leading to this increase in anesthetized mechanically ventilated dogs. Cardiac output was maintained nearly constant before and during PEEP, and heart rate did not change. Left atrial pressure measured relative to pleur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 91 1 شماره
صفحات -
تاریخ انتشار 2001