Automation of the BD GeneOhm methicillin-resistant Staphylococcus aureus assay for high-throughput screening of nasal swab specimens.
نویسندگان
چکیده
This study demonstrated that an automated version of the BD-GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) assay (BD-MRSA), using achromopeptidase sample lysis and PCR setup performed on the Hamilton MICROLAB STAR(let) (Auto-MRSA), gave results comparable to those obtained with BD-MRSA. The positive- and negative-result concordance rates and overall concordance of BD-MRSA and Auto-MRSA were 98.2, 97.7, and 97.6%, respectively. Auto-MRSA required 60% less technical time than BD-MRSA, and the time required to obtain results was 50% of that required for BD-MRSA. Auto-MRSA provides a reliable, robust system for high-volume clinical use.
منابع مشابه
Evaluation of the BD GeneOhm MRSA and VanR Assays as a Rapid Screening Tool for Detection of Methicillin-Resistant Staphylococcus aureus and Vancomycin-Resistant Enterococci in a Tertiary Hospital in Saudi Arabia
Objectives. The aim of this study was to evaluate the diagnostic performance of BD GeneOhm VanR Assay, a rapid PCR test that detects the presence of vanA and/or vanB genes and the performance of BDGeneOhm MRSA Assay which detects the staphylococcal cassette chromosomemec (SCCmec cassette) carrying the mecA gene and Staphylococcus aureus specific sequence located within the orfX gene. Methods. 3...
متن کاملComparison of BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR versus the CHROMagar MRSA assay for screening patients for the presence of MRSA strains.
We compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay with the CHROMagar MRSA assay for the detection of MRSA in 286 nasal surveillance specimens. Compared with the CHROMagar MRSA assay, PCR had sensitivity, specificity, positive predictive value, and negative predictive values of 100%, 98.6%, 95.8%, and 100%, respectively. The mean PCR turnaround tim...
متن کاملRapid detection of Methicillin-Resistant Staphylococcus aureus MRSA in nose, groin, and axilla swabs by the BD GeneOhm MRSA achromopeptidase assay and comparison with culture.
OBJECTIVES To compare the BD GeneOhm Methicillin Resistant Staphylococcus aureus (MRSA) Achromopeptidase (ACP) polymerase chain reaction (PCR) assay with the culture method for the detection of MRSA colonization. METHODS One hundred and two patients were admitted to the Intensive Care Unit in King Khalid Hospital, Najran, Kingdom of Saudi Arabia from July 2010 to February 2011. Separate swabs...
متن کاملEvaluation of the BD GeneOhm StaphSR assay for detection of Staphylococcus aureus in patients in intensive care units.
BACKGROUND Staphylococcus aureus is the major nosocomial pathogen and rapid detection of colonized patients with subsequent precaution is needed to prevent transmission. A new assay, the BD GeneOhm™ SaphSR assay (BD GeneOhm™, San Diego, CA, USA), is a multiplex real-time polymerase chain reaction (PCR) for rapid detection of both methicillin-sensitive S aureus (MSSA) as well as methicillin-resi...
متن کاملPerformance of the BD GeneOhm methicillin-resistant Staphylococcus aureus test before and during high-volume clinical use.
We evaluated the use of the BD GeneOhm MRSA real-time PCR assay (BD Diagnostics, San Diego, CA) for the detection of nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA). The initial evaluation consisted of 403 paired nasal swabs and was done using the specimen preparation provided with the kit and an in-house lysis method that was specifically developed to accommodate lar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 47 5 شماره
صفحات -
تاریخ انتشار 2009