Coronary CT angiography.

نویسندگان

  • Udo Hoffmann
  • Maros Ferencik
  • Ricardo C Cury
  • Antonio J Pena
چکیده

Advances in multidetector CT (MDCT) technology with submillimeter slice collimation and high temporal resolution permit contrast-enhanced imaging of coronary arteries and coronary plaque during a single breath hold. Appropriate patient preparation, detailed technical and technological knowledge with regard to recognition of typical imaging artifacts (such as beam hardening or motion artifacts), and the adequate choice of postprocessing techniques to detect stenosis and plaque are prerequisites to achieving diagnostic image quality. A growing number of studies have suggested that 64-slice coronary CT angiography is highly accurate for the exclusion of significant coronary artery stenosis (>50% luminal narrowing), with negative predictive values of 97%-100%, in comparison with invasive selective coronary angiography. In addition, several studies have indicated that MDCT also can detect calcified and noncalcified coronary atherosclerotic plaques, especially in proximal vessel segments, showing a good correlation with intracoronary ultrasound. Studies on clinical utility, cost, and cost-effectiveness are now warranted to demonstrate whether and how this technique can change and improve the current management of patients with suspected or confirmed coronary artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

منشأ گرفتن کرونر چپ از سینوس راست آئورت: گزارش سه مورد

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tsty...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Coronary CT angiography: current status and continuing challenges.

Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alterna...

متن کامل

Radiation dose associated with coronary CT angiography and invasive coronary angiography: an experimental study of the effect of dose-saving strategies.

This study was conducted on a human anthropomorphic phantom to investigate the effective dose and entrance skin dose (ESD) in selected radiosensitive organs through invasive and computed tomography (CT) coronary angiography procedures using different dose-saving techniques. The effective dose was calculated as 2.49, 3.35 and 9.62 mSv, respectively, corresponding to three coronary CT angiography...

متن کامل

Coronary CT angiography versus standard emergency department evaluation for acute chest pain and diabetic patients: Is there benefit with early coronary CT angiography? Results of the randomized comparative effectiveness ROMICAT II trial

Coronary CT angiography versus standard emergency department evaluation for acute chest pain and diabetic patients: Is there benefit with early coronary CT angiography? Results of the randomized comparative effectiveness ROMICAT II trialCoronary CT angiography versus standard emergency department evaluation for acute chest pain and diabetic patients: Is there benefit with early coronary CT angi...

متن کامل

Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value.

Multislice computed tomography (CT) angiography has been increasingly used in the detection and diagnosis of coronary artery disease because of its rapid technical evolution from the early generation of 4-slice CT scanners to the latest models such as 64-slice, 256-slice and 320-slice CT scanners. Technical developments of multislice CT imaging enable improved diagnostic value in the detection ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2006