Relationship between diseased lung tissues on computed tomography and motion of fiducial marker near lung cancer.
نویسندگان
چکیده
PURPOSE For lung cancer patients with poor pulmonary function because of emphysema or fibrosis, it is important to predict the amplitude of internal tumor motion to minimize the irradiation of the functioning lung tissue before undergoing stereotactic body radiotherapy. METHODS AND MATERIALS Two board-certified diagnostic radiologists independently assessed the degree of pulmonary emphysema and fibrosis on computed tomography scans in 71 patients with peripheral lung tumors before real-time tumor-tracking radiotherapy. The relationships between the computed tomography findings of the lung parenchyma and the motion of the fiducial marker near the lung tumor were investigated. Of the 71 patients, 30 had normal pulmonary function, and 29 had obstructive pulmonary dysfunction (forced expiratory volume in 1 s/forced vital capacity ratio of <70%), 6 patients had constrictive dysfunction (percentage of vital capacity <80%), and 16 had mixed dysfunction. RESULTS The upper region was associated with smaller tumor motion, as expected (p = .0004), and the presence of fibrosis (p = .088) and pleural tumor contact (p = .086) were weakly associated with tumor motion. The presence of fibrotic changes in the lung tissue was associated with smaller tumor motion in the upper region (p <.05) but not in the lower region. The findings of emphysema and pulmonary function tests were not associated with tumor motion. CONCLUSION Tumors in the upper lung region with fibrotic changes have smaller motion than those in the upper region of the lungs without fibrotic changes. The tumor motion in the lower lung region was not significantly different between patients with and without lung fibrosis. Emphysema was not associated with the amplitude of tumor motion.
منابع مشابه
Optimal surface marker locations for tumor motion estimation in lung cancer radiotherapy.
Using fiducial markers on the patient's body surface to predict the tumor location is a widely used approach in lung cancer radiotherapy. The purpose of this work is to propose an algorithm that automatically identifies a sparse set of locations on the patient's surface with the optimal prediction power for the tumor motion. In our algorithm, it is assumed that there is a linear relationship be...
متن کاملStereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters
Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...
متن کاملبررسی رابطه پلیمورفیسم در جایگاه اتصال miR-214 در ژن EGFR با سرطان ریه
Background and Aim: Lung cancer is the most common cause of cancer-related deaths wordwide and non-small cell lung cancer (NSCLC), especially adenocarcinoma, is the most common type of lung cancer. Most cases of adenocarcinoma will occur due to KRAS mutations or EGFR mutations and amplifications. The polymorphism rs884225 which is associated with increased EGFR expression is located in the 3'UT...
متن کاملComment on “Computed Tomography Imaging Findings in Chemical Warfare Victims with Pulmonary Complications”
Dr.Mirsadraei and colleagues performed an interesting study about the lung HRCT findings in chemical warfare patients who suffering from long-term pulmonary complications. They found that air trapping and mosaic attenuation were the most common lung HRCT findings. Also they divided patients in different clinical entities according to the lung HRCT findings (Bronchiolitis Oblitrans, pulmonary fi...
متن کاملEvaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study
Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 79 5 شماره
صفحات -
تاریخ انتشار 2011