Evaluation of a novel kit for use with the BacT/ALERT 3D system for drug susceptibility testing of Mycobacterium tuberculosis.

نویسندگان

  • Jim Werngren
  • Lisbeth Klintz
  • Sven E Hoffner
چکیده

We evaluated a new protocol for the BacT/ALERT MB susceptibility test (bioMérieux Inc., Durham, NC) using 80 Mycobacterium tuberculosis WHO challenge panel strains. The drug susceptibility profiles of these strains are well characterized, and consensus drug resistance results have been established after tests were performed at around 20 international reference laboratories using recommended reference drug susceptibility techniques. Strains were tested according to the bioMérieux protocol using the following critical concentrations: rifampin (RIF), 0.9 mg/liter; isoniazid (INH), 0.4 and 0.09 mg/liter; and ethambutol (EMB), 1.8 mg/liter. The BacT/ALERT system detected 36/37 RIF-resistant strains. For INH (low concentration), 59/59 resistant strains were detected, and for EMB, 34/34 resistant strains were detected. Thus, the sensitivities were 97%, 100%, and 100% for RIF, INH, and EMB, respectively. The corresponding specificities were 100%, 95%, and 98%, respectively, for the same drugs. As soon as the BacT/ALERT MP seed bottle flagged positive, the median time to obtain a susceptibility results was 7.8 days. The results show good concordance with the consensus results of the international reference laboratories and demonstrate that BacT/ALERT 3D should be considered as an alternative method for rapid and automated drug susceptibility testing of M. tuberculosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the BacT Alert 3D System Versus Solid Media for Recovery and Drug Susceptibility Testing of Mycobacterium tuberculosis in a Tertiary Hospital in Korea

BACKGROUND Tuberculosis (TB) is a major health problem, and accurate and rapid diagnosis of multidrug-resistant (MDR) and extended drug-resistant (XDR) TB is important for appropriate treatment. In this study, performances of solid and liquid culture methods were compared with respect to MDR- and XDR-TB isolate recovery and drug susceptibility testing. METHODS Sputum specimens from 304 patien...

متن کامل

Evaluation of the BacT/ALERT PZA kit in comparison with the BACTEC 460TB PZA for testing Mycobacterium tuberculosis susceptibility to pyrazinamide.

OBJECTIVES To compare the performance of the BacT/ALERT PZA kit (BioMerieux, Marcy l'Etoile, France) with the radiometric BACTEC 460TB PZA test (Becton-Dickinson method) for testing Mycobacterium tuberculosis susceptibility to pyrazinamide. METHODS A total of 50 M. tuberculosis strains were tested. Thirty of these strains had been previously considered pyrazinamide-susceptible and 20 pyrazina...

متن کامل

Standardization of first and second-line antitubercular susceptibility testing using BacT Alert 3D system: a report from a tertiary care centre in India.

Resurgence of multidrug resistant tuberculosis has lead to demand for rapid susceptibility testing. Conventional methods take > 3 weeks and are tedious. Automated methods have superseded them for first line drug susceptibility testing. An attempt was made to standardize first and second line susceptibility testing using the BacT Alert 3D system (Biomerieux). And compare results with Lowenstein ...

متن کامل

Comparative evaluation of Löwenstein-Jensen proportion method, BacT/ALERT 3D system, and enzymatic pyrazinamidase assay for pyrazinamide susceptibility testing of Mycobacterium tuberculosis.

Pyrazinamide (PZA) is an important first-line antituberculosis drug because of its sterilizing activity against semidormant tubercle bacilli. In spite of its very high in vivo activity, its in vitro activity is not apparent unless an acidic environment is available, which makes PZA susceptibility testing difficult by conventional methods. The present study was, therefore, planned to assess the ...

متن کامل

Evaluation of BacT/ALERT 3D System for Mycobacteria Isolates

Background: The rapid diagnosis of mycobacterial infections is essential to implement the adequate antimicrobial therapy. This study evaluates the performance of the BacT/ALERT 3D system for isolates and identification of mycobacteria from clinical samples. Methods: 1011 clinical specimens from nonsterile and sterile body sites were studied from August 2010 to December 2012 at the National Refe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 6  شماره 

صفحات  -

تاریخ انتشار 2006