Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass spectrometry.
نویسندگان
چکیده
BACKGROUND Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. METHODS We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with positive-mode electrospray ionization. RESULTS The DHT and T calibrators showed a linear response from 0.069 nmol/L to 34.4 nmol/L and 69.3 nmol/L, respectively. T interference in the DHT assay and vice versa were negligible. Within- and between-run imprecision values were <5% for both analytes. Percent recoveries of T and DHT spiked into samples at concentrations spanning the calibration curve were 100%-113% and 98%-107%, respectively. The lower limit of quantification was 0.069 nmol/L for both steroids. Serum T concentrations measured by LC-MS/MS were different from those obtained by RIA, especially at lower T concentrations. Serum DHT concentrations measured by LC-MS/MS were markedly lower than those generated by RIA because of the nonselectivity of the RIA without chromatography. The reference intervals (mean +/- 2 SDs) determined for T and DHT were 9.2-33.7 nmol/L and 0.47-2.65 nmol/L, respectively, for 113 healthy adult men and 0.33-2.02 nmol/L and 0.09-0.91 nmol/L, respectively, for 133 healthy premenopausal women. CONCLUSIONS We have developed and validated a selective and precise method for simultaneous measurements of serum T and DHT that can be adopted for routine measurements of these androgens in health and disease in men and women.
منابع مشابه
Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS).
Monitoring complex endocrine pathways is often limited by indirect measurement or measurement of a single hormone class per analysis. There is a burgeoning need to develop specific direct-detection methods capable of providing simultaneous measurement of biologically relevant concentrations of multiple classes of hormones (estrogens, androgens, progestogens, and corticosteroids). The objectives...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملSimultaneous pharmacokinetic and pharmacodynamic analysis of 5α-reductase inhibitors and androgens by liquid chromatography tandem mass spectrometry
Benign prostatic hyperplasia and prostate cancer can be treated with the 5α-reductase inhibitors, finasteride and dutasteride, when pharmacodynamic biomarkers are useful in assessing response. A novel method was developed to measure the substrates and products of 5α-reductases (testosterone, 5α-dihydrotestosterone (DHT), androstenedione) and finasteride and dutasteride simultaneously by liquid ...
متن کاملDevelopment and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 54 11 شماره
صفحات -
تاریخ انتشار 2008