Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring

نویسندگان

  • Satoshi Ugi
  • Hiroshi Maegawa
  • Katsutaro Morino
  • Yoshihiko Nishio
  • Toshiyuki Sato
  • Seiki Okada
  • Yasuo Kikkawa
  • Toshihiro Watanabe
  • Hiromu Nakajima
  • Atsunori Kashiwagi
چکیده

BACKGROUND Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. METHODS Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. RESULTS AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. CONCLUSION Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a minimally invasive system for measuring glucose area under the curve during oral glucose tolerance tests: usefulness of sweat monitoring for precise measurement.

AIMS We developed a system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET). Sweat contamination during interstitial fluid glucose (IG) extraction affects the accuracy of glucose AUC measurement, because this technology uses extracted sodium ion levels as an internal standard. Therefore, we developed a sweat monitoring pat...

متن کامل

Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

BACKGROUND Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC meas...

متن کامل

اثرات تستوسترون بر تست تحمل گلوکز در بیماران هیپوگونادیسم‌

ABSTRACT The Purpose of this study is to compare the means of glucose area under the curve (AUC) before and after testosterone enanthate injection in men with hypogonadotropic hypogonadism. Oral glucose tolerance test was done in subjects selected before and after one week of testosterone injection and compared with control group. 20 men with hypogonadotropic hypogonadism referred to resear...

متن کامل

Evaluation of a novel continuous glucose monitoring-based method for mealtime insulin dosing--the iBolus--in subjects with type 1 diabetes using continuous subcutaneous insulin infusion therapy: a randomized controlled trial.

OBJECTIVE Prandial insulin dosing is an empirical practice associated frequently with poor reproducibility in postprandial glucose response. Based on continuous glucose monitoring (CGM), a method for prandial insulin administration (iBolus) is presented and evaluated for people with type 1 diabetes using CSII therapy. SUBJECTS AND METHODS An individual patient's model for a 5-h postprandial p...

متن کامل

Usefulness of a novel system for measuring glucose area under the curve while screening for glucose intolerance in outpatients†

AIMS/INTRODUCTION To realize the effectiveness of a novel system for measuring glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET), outpatients undergoing oral glucose tolerance tests (OGTT) were investigated for the efficacy of screening for glucose intolerance using this system. MATERIALS AND METHODS Fifty outpatients scheduled to unde...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 40  شماره 

صفحات  -

تاریخ انتشار 2016