Using a Powered Bone Marrow Biopsy System Results in Shorter Procedures, Causes Less Residual Pain to Adult Patients, and Yields Larger Specimens
نویسندگان
چکیده
BACKGROUND In recent years, a battery-powered bone marrow biopsy system was developed and cleared by the U.S. Food and Drug Administration to allow health care providers to access the bone marrow space quickly and efficiently. A multicenter randomized clinical trial was designed for adult patients to determine if the powered device had advantages over traditional manually-inserted needles in regard to length of procedure, patient pain, complications, user satisfaction, and pathological analysis of the specimens. METHODS Adult patients requiring marrow sampling procedures were randomized for a Manual or Powered device. Visual Analog Scale (VAS) pain scores were captured immediately following the procedure and 1 and 7 days later. Procedure time was measured and core specimens were submitted to pathology for grading. RESULTS Ten sites enrolled 102 patients into the study (Powered, n = 52; Manual, n = 50). Mean VAS scores for overall procedural pain were not significantly different between the arms (3.8 ± 2.8 for Powered, 3.5 ± 2.3 for Manual [p = 0.623]). A day later, more patients who underwent the Powered procedure were pain-free (67%) than those patients in the Manual group (33%; p = 0.003). One week later, there was no difference (83% for Powered patients; 76% for Manual patients.) Mean procedure time was 102.1 ± 86.4 seconds for the Powered group and 203.1 ± 149.5 seconds for the Manual group (p < 0.001). Pathology assessment was similar in specimen quality, but there was a significant difference in the specimen volume between the devices (Powered: 36.8 ± 21.2 mm3; Manual: 20.4 ± 9.0 mm3; p = 0.039). Two non-serious complications were experienced during Powered procedures (4%); but none during Manual procedures (p = 0.495). CONCLUSIONS The results of this first trial provide evidence that the Powered device delivers larger-volume bone marrow specimens for pathology evaluation. In addition, bone marrow specimens were secured more rapidly and subjects experienced less intermediate term pain when the Powered device was employed. Further study is needed to determine if clinicians more experienced with the Powered device will be able to use it in a manner that significantly reduces needle insertion pain; and to compare a larger sample of pathology specimens obtained using the Powered device to those obtained using traditional manual biopsy needles.
منابع مشابه
Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices
Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bila...
متن کاملGeneral Anesthesia for Lumbar Puncture and Bone Marrow Aspiration /Biopsy in Children
Background Multiple procedures (Lumbar puncture and bone marrow aspiration /biopsy) cause pain, stress, depression and etc for the patients and their families. Various methods have been recommended for pain reduction during invasive procedures. The aim of this study is to report the complications following general anesthesia. Methods In this prospective observational study, two hundred and ...
متن کاملGeneral Anesthesia for Lumbar Puncture and Bone Marrow Aspiration /Biopsy in Children with Cancer
Abstract Background Multiple procedures (Lumbar puncture and bone marrow aspiration /biopsy) cause pain, stress, depression and etc for the patients and their families. Various methods have been recommended for pain reduction during invasive procedures. The aim of this study is to report the complications following general anesthesia. Materials and Methods In this prospective observational ...
متن کاملComparison of a powered bone marrow biopsy device with a manual system: results of a prospective randomised controlled trial
The diagnostic and clinical usefulness of a powered bone marrow biopsy device (OnControl()) versus a standard manual device (TRAP Hospital System) was studied. Primary endpoints were biopsy quality and patient pain during the procedure. Fifty patients underwent a total of 60 procedures by three expert operators in a randomised stratified fashion. Baseline demographic and clinical parameters wer...
متن کاملA powered bone marrow biopsy system versus manual methods: a systematic review and meta-analysis of randomised trials
A significant number of bone marrow biopsies are performed annually. Outcomes of patient pain and sample size of biopsy are important issues as perception of patient pain is underestimated by clinicians and sample size assists in accurate diagnosis. Manual extraction of marrow biopsy is the main method used. Recently a powered system has been introduced. The objectives of this systematic review...
متن کامل