Duelling pacemakers: Unexpected pacemaker interaction resulting from a proprietary rate smoothing algorithm

نویسندگان

  • Justin M. Cloutier
  • Colette M. Seifer
  • Clarence Khoo
چکیده

Case Report An 89-year-old man had a left-sided dual-chamber pacemaker (Symphony DR; Sorin CRM, Clamart, France) implanted for syncope, second-degree Mobitz II heart block, and periodic third-degree heart block. He was found to have an abrupt increase in right ventricular lead impedance and high capture thresholds, consistent with an impending lead fracture. Owing to occlusion of the left innominate vein, the left-sided pacemaker was abandoned and a new dualchamber pacemaker was implanted on the right side (Reply DR; Sorin CRM) and programmed to DDD 60–130 ppm. Paced and sensed atrioventricular (AV) delays were 220 msec and 165 msec, respectively. Given that the patient was dependent on ventricular pacing (VP), the original left-sided device was set with a backup rate of VVI at 40 ppm in case of early dislodgement of the new right-sided lead. The patient was seen in follow-up 1 month later. The devices were interrogated and it was found that the original left-sided device was pacing approximately 75% of the time (Figures 1 and 2). Thus, despite the abandoned device’s being programmed at a backup rate slower than the lower

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Capture Verification in Pacemakers (Autocapture) - Utility and Problems

The concept of a closed – loop feedback system, that would automatically assess pacing threshold and self -adjust pacing output to ensure consistent myocardial capture, has many appeals. Enhancing patient safety in cases of an unexpected rise in threshold, reduced current drain, hence prolonging battery longevity and reducing the amount of physician intervention required are just some of the ad...

متن کامل

THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS

The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Mammalian genome evolution is governed by multiple pacemakers

UNLABELLED Genomic evolution is shaped by a dynamic combination of mutation, selection and genetic drift. These processes lead to evolutionary rate variation across loci and among lineages. In turn, interactions between these two forms of rate variation can produce residual effects, whereby the pattern of among-lineage rate heterogeneity varies across loci. The nature of rate variation is encap...

متن کامل

Reuse of pacemakers: comparison of short and long-term performance.

BACKGROUND In developing economies, there are patients in whom pacemaker implantation is delayed because they cannot afford one. Reused devices have been a solution. To address concerns about safety, a cohort of consecutive patients implanted with a reused pacemaker was compared with a control group. METHODS AND RESULTS A cohort of 603 consecutive patients from 2000 to 2010 was studied in an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015