Utility of cardiac monitoring in fetuses at risk for congenital heart block: the PR Interval and Dexamethasone Evaluation (PRIDE) prospective study.

نویسندگان

  • Deborah M Friedman
  • Mimi Y Kim
  • Joshua A Copel
  • Claudine Davis
  • Colin K L Phoon
  • Julie S Glickstein
  • Jill P Buyon
چکیده

BACKGROUND Anti-SSA/Ro-associated third-degree congenital heart block is irreversible, prompting a search for early markers and effective therapy. METHODS AND RESULTS One hundred twenty-seven pregnant women with anti-SSA/Ro antibodies were enrolled; 95 completed an evaluable course in 98 pregnancies. The protocol included fetal echocardiograms performed weekly from 16 to 26 weeks' gestation and biweekly from 26 to 34 weeks. PR intervals >150 ms were considered prolonged, consistent with first-degree block. Ninety-two fetuses had normal PR intervals. Neonatal lupus developed in 10 cases; 4 were neonatal lupus rash only. Three fetuses had third-degree block; none had a preceding abnormal PR interval, although in 2 fetuses >1 week elapsed between echocardiographic evaluations. Tricuspid regurgitation preceded third-degree block in 1 fetus, and an atrial echodensity preceded block in a second. Two fetuses had PR intervals >150 ms. Both were detected at or before 22 weeks, and each reversed within 1 week with 4 mg dexamethasone. The ECG of 1 additional newborn revealed a prolonged PR interval persistent at 3 years despite normal intervals throughout gestation. No first-degree block developed after a normal ECG at birth. Heart block occurred in 3 of 16 pregnancies (19%) in mothers with a previous child with congenital heart block and in 3 of 74 pregnancies (4%) in mothers without a previous child with congenital heart block or rash (P=0.067). CONCLUSIONS Prolongation of the PR interval was uncommon and did not precede more advanced block. There was a trend toward more congenital heart block in fetuses of women with previously affected offspring than those without previously affected offspring. Advanced block and cardiomyopathy can occur within 1 week of a normal echocardiogram without initial first-degree block. Echodensities and moderate/severe tricuspid regurgitation merit attention as early signs of injury.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CONGENITAL HEART DISEASE Clinical course of fetal congenital atrioventricular block in the Japanese population: a multicentre experience

Objectives: To elucidate the prenatal and postnatal course of fetal congenital atrioventricular block (CAVB) during the past decade in the Japanese population. Design: Retrospective multicentre study. All fetuses with CAVB in 10 Japanese institutions in the period from January 1990 to August 2001 were included. Patients: Of the 48 fetuses with CAVB, 17 had a congenital heart defect (CHD) (14 wi...

متن کامل

Fetal Echo Doppler for Early Detection of Congenital Heart Block

Background: Fetal echo Doppler methods, detecting prolonged atrioventricular (AV) time intervals a mechanical PR interval corresponding to the electrical PR interval in ECG, have been proposed for surveillance of pregnancies at risk of complete congenital heart block (CCHB). The aim of this thesis was; to validate these Doppler methods by comparing AV time intervals from left ventricular inflow...

متن کامل

Clinical course of fetal congenital atrioventricular block in the Japanese population: a multicentre experience.

OBJECTIVES To elucidate the prenatal and postnatal course of fetal congenital atrioventricular block (CAVB) during the past decade in the Japanese population. DESIGN Retrospective multicentre study. All fetuses with CAVB in 10 Japanese institutions in the period from January 1990 to August 2001 were included. PATIENTS Of the 48 fetuses with CAVB, 17 had a congenital heart defect (CHD) (14 w...

متن کامل

Early diagnosis and treatment of atrioventricular block in the fetus exposed to maternal anti-SSA/Ro-SSB/La antibodies: a prospective, observational, fetal kinetocardiogram-based study.

BACKGROUND A fetus exposed to maternal anti-SSA/Ro or anti-SSB/La antibodies (or both) may develop complete atrioventricular block (AVB), which results in high prenatal and postnatal morbidity and mortality. Until recently, only high-grade AVB could be diagnosed in utero. The tissue velocity-based fetal kinetocardiogram (FKCG) enables accurate measurement of AV conduction time and diagnosis of ...

متن کامل

Doppler echocardiographic and electrocardiographic atrioventricular time intervals in newborn infants: evaluation of techniques for surveillance of fetuses at risk for congenital heart block.

OBJECTIVE To evaluate one novel and two previously reported Doppler flow velocimetric techniques to estimate atrioventricular (AV) time intervals, suggested to be useful for early identification of fetuses at risk for congenital heart block. METHODS In 22 newborn infants, Doppler tracings were obtained from the mitral valve/aortic outflow and the superior vena cava/ascending aorta, as an ECG ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 117 4  شماره 

صفحات  -

تاریخ انتشار 2008