Diagnosis of the air distribution system of the JAS39 Gripen environmental control system

نویسنده

  • Johan Karlsson
چکیده

Traditionally supervision has been achieved using limit checking and hardware redundancy, but these methods have proven insufficient. The availability of information from all parts of the aircraft and the computing capacity available in the Gripen today enables the implementation of sophisticated supervision methods, for instance model based diagnosis. The purpose of this thesis was to investigate which faults in the distribution part of the Environmental Control System (ECS) could be detected with the sensors available today, using model based diagnosis, and to clarify where new ones could be useful in order to design an improved diagnosis system. No measurement data from a real ECS could be obtained, so the real system had to be replaced by an Easy5-model. Therefore the diagnosis system developed in this thesis is not directly applicable on a real ECS. With the sensors available, 8 of the 9 faults important to detect, can be detected. The last important fault can be detected if one new pressure is installed. Acknowledgements This work has been carried out in cooperation with Saab AB. I would like to thank my two supervisors, Erik Frisk, LiTH, and Birgitta Lantto, Saab AB, for all their help and guidance. I would also like to thank the two groups GDGT and GDGM at Saab, for all pleasant coffeebreaks. A special thanks to Per Nilsson and Mikael Holmberg for making me feel so welcome at the office. Linköping, February 2001 Johan Karlsson

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Experimental Analysis of Aircraft Air Distribution Systema

In this paper, the methodology of aircraft air distribution system has been analyzed theoretically and experimentally. To achieve that, ducting pressure loss and air flow throw gaspers calculations has been done for cabin ducts in according to exact location of individual air distribution system in the cabin. The length of gasper air flow was compared with the distance between gasper outlet and...

متن کامل

Investigation of the Benzene Concentration and Distribution in Tehran Using Geographic Information System Modelling

Introduction and purpose: Air pollution has been recognized as the most important environmental risk factor worldwide. Benzene which is one of the four pollutants attributed to BTEX (Benzene, Toluene, Ethylbenzene, and Xylene) has been proven to be a carcinogenic component. These pollutants can be easily absorbed and taken into the body via inhalation. With this background in mind, the present ...

متن کامل

Validation Techniques Applied on the Saab Gripen Fighter Environmental Control System Model

The Environmental Control System (ECS) of the Saab Gripen fighter provides a number of vital functions, such as provision of coolant air to the avionics, comfort air to the cockpit, and pressurization of the aircraft fuel system. To support system design, a detailed simulation model has been developed in the Modelica-based tool Dymola. The model needs to be a “good system representation”, durin...

متن کامل

Design of Air Distribution System for Operation Theatre Using Flow Visualization Techniques to Improve Flow Characteristics

Operation Theatre (OT) is the most important area where precise controlled on indoor air quality is required because it is directly related to patient health and its recovery period. This work aims to study and visualize the airflow distribution of conventional flat air diffuser ventilation system and newly designed angular air ventilation system in OT. Angular Air Distribution (AAD) system is ...

متن کامل

Introduction and Application of New GIS_AQI Model: Integrated Pollution Control in Tehran

The city of Tehran undergoes an increasing growth in population as well as industrial activities, both of which increase the concentration of air pollutants. The current research tries to turn a limited and focused system of air contamination measurement and control to an unlimited and extensive one that examines the concentration of each of the contaminants in any area of Tehran. Accordingly, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001