Flow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing

نویسندگان

  • Bo Young Seo
  • Dong Il Won
چکیده

BACKGROUND Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. METHODS WE COMPARED FOUR STORAGE METHODS: three methods of analyzing lymphocytes (whole blood stored at room temperature, frozen mononuclear cells, and frozen white blood cells [WBCs] after lysing red blood cells [RBCs]), and one method using frozen platelets (FPLT). We used three ratios associated with mean fluorescence intensities (MFI) for HLAB27 assignment: the B27 MFI ratio (sample/control) for HLA-B27 fluorescein-5-isothiocyanate (FITC); the B7 MFI ratio for HLA-B7 phycoerythrin (PE); and the ratio of these two ratios, B7/B27 ratio. RESULTS Comparing the B27 MFI ratios of each storage method for the HLA-B27+ samples and the B7/B27 ratios for the HLA-B7+ samples revealed that FPLT was the best of the four methods. FPLT had a sensitivity of 100% and a specificity of 99.3% for HLA-B27 assignment in DNA-typed samples (N=164) when the two criteria, namely, B27 MFI ratio >4.0 and B7/B27 ratio <1.5, were used. CONCLUSIONS The FPLT method was found to offer a simple, economical, and accurate method of FC HLA-B27 typing by using stored patient samples. If stored samples are used, this method has the potential to replace the standard FC typing method when used in combination with a complementary DNA-based method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human Leukocyte Antigen B27 in 453 Asian Indian Patients with Seronegative Spondyloarthropathy

Background: Spondyloarthropathies are a group of closely related inflammatory arthritis which involve the axial skeleton and are negative for rheumatoid factor. Objective: This case-control study was conducted to examine HLA- B27 positivity in patients with seronegative spondyloarthritis (SSA) as per ESSG criteria and compare the frequency with healthy controls because a lower positivity is rep...

متن کامل

HLA-B27 screening by flow cytometry.

A flow cytometric assay for lymphocyte HLA-B27 expression using a two-color direct immunofluorescent assay was compared to traditional microlymphocytotoxicity testing on 209 clinical samples. For the flow cytometric assay, whole blood was mixed with a monoclonal anti-B27 conjugated to fluorescein-isothiocyanate (FITC) and anti-CD3 conjugated to phycoerythrin (PE). The samples were analyzed with...

متن کامل

HLA-B27 phenotyping with flow cytometry: further improvement by multiple monoclonal antibodies.

To establish the optimal flow cytometric method for HLA-B27 phenotyping, we compared several strategies, using three monoclonal anti-B27 antibodies (from the HLA-ABC-m3, GS145.2, and FD705 clones). We used a triple-color direct immunofluorescence assay, including a T-lymphocyte-specific antibody as an internal control and an anti-HLA-Bw4 antibody. Blood samples from >400 subjects were tested. F...

متن کامل

COMPARISON OF VAL IDITY OF MICROLYMPHOCYTOTOXICITY AND FLOWCYTOMETRY METHODS WITH PCR FOR HL A-B27 ANTIGEN TYPING

The Human Major Histocompatibility Complex (MHC) plays a crucial role in transplantation, transfusion, paternity test and assessment of susceptibility to some diseases associated with HLA-B27. Three of the most fashionable methods for determination of HLA antigens in clinical and research laboratories are microlymphocytotoxicity (MLCT), flowcytometry and polymerase chain reaction (PCR). T...

متن کامل

The flow cytometric labeling pattern in HLA-B27 detection may suggest cross reactivities

Background: The detection of HLA-B27 expression is one of the most powerful diagnostic tools in ankylosing spondylitis and other spondylarthropaties, hence the importance of a reliable and accurate detection method. Flow cytometry is often used as an alternative HLA-B27 typing technique, mainly because it is a rapid test. However, even though it is based on various monoclonal antibodies, their ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2013