Management of diaphyseal tibial fractures by plate fixation with absolute or relative stability: a retrospective study of 45 patients

نویسندگان

  • Juan Manuel Concha Sandoval
  • José Luis Osma Rueda
  • Alejandro Sandoval Daza
چکیده

To cite: Concha Sandoval JM, Osma Rueda JL, Sandoval Daza A. Trauma Surg Acute Care Open Published Online First: [please include Day Month Year] doi:10.1136/tsaco2016-000029 ABSTRACT Background Fixation of diaphyseal tibial fractures by plates is not considered the best option due to complications that may eventually arise; however, if principles of stability and proper surgical techniques are used, it is possible to obtain fracture consolidation without major risks. Methods We conducted a cross-sectional observational descriptive study by retrospectively analyzing medical records of patients with diaphyseal tibial fractures that were treated with plates from the period between June 2011 and June 2014 at San José and Susana López Hospitals in the city of Popayan, Colombia. 3 treatment groups were created and analyzed according to the type of fracture (Association Osteosynthesis/Osteosynthesis Trauma Association AO/OTA): group I: simple fractures 42A/B, absolute stability; group II: simple fractures 42A/ B, Minimally Invasive Plate Osteosynthesis (MIPO) technique, relative stability; group III: multifragmentary fractures 42C, MIPO technique, relative stability. A descriptive analysis of patients, fracture consolidation time, and complications in each group were performed. Results 45 patients with tibial fractures treated with osteosynthesis plates were analyzed. Group I: 14 patients, 42A (n=13) and 42B (n=1), had an average consolidation time of 16.38 (SD=1.98) and 14 weeks, respectively. In group II: 19 patients, out of which 18 achieved fracture consolidation (42A n=15 and 42B n=3) with an average time of 17.4 (SD=3.33) and 17.3 weeks (SD=6.11), respectively. Finally, in group III: 12 patients all with 42C fractures with a consolidation time of 16.86 (SD=2.93) weeks. The average fracture consolidation time for all 44 patients was 16.86 weeks (SD 2.93). Conclusions Osteosynthesis plates are an alternative to intramedullary nailing for diaphyseal tibial fractures and their outcomes can be favorable as long as the management of soft tissues and the proper principle of stability are taken into account. Level of evidence IV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Tibial Tuberosity Avulsion Fracture and Open Proximal Tibial Fracture in an Adult

A displaced tibial tuberosity avulsion fracture associated with an open extra-articular proximal tibial diaphyseal fracture is an uncommon fracture pattern. This case report describes the successful management of such a fracture pattern in a 45-year old male using an open reduction and lag screw fixation of the tuberosity with a minimally invasive reduction and plate fixation of the proximal ti...

متن کامل

Minimally invasive osteosynthesis of adult tibia fractures by means of rigid fixation with anatomic locked plates

Main principle of biological fixation by minimally invasive locked plate osteosynthesis (MILPO) in lower extremity long bone fractures is relative stability which is provided by using long plate with limited number of screws. Some biomechanical studies have been reported about this issue. However, clinical studies are still missing. The aims of this retrospective extended case series were to ev...

متن کامل

Treatment of tibial diaphyseal fractures with closed flexible intramedullary ender nails: 39 fractures followed for a period of two to seven years.

OBJECTIVE To assess the efficacy of flexible intramedullary Ender nails for the treatment of tibial diaphyseal. MATERIALS AND METHODS This is a retrospective review of patients treated with the Ender Nail for both open and closed tibial shaft fractures. Between January 1989 and December 1994, 43 fractures were treated with these nails. The configuration of each fracture was determined using t...

متن کامل

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017