Measurement of Myocardial Blood Flow

نویسندگان

  • THOMAS MARCHIORO
  • ARNOLD FELDMAN
  • J. CUTHBERT OWENS
  • HENRY SWAN
چکیده

A"CLOSED" method for the accurate measurement of myocardial blood flow is still to be achieved. In 1956, Henly et al. described an indicator-dilution technique for assessing myocardial blood flow. This approach led us to construct a suitable model for simulating a systemic-coronary circuit. Observations with this system suggested that an indicator-dilution technique might be applicable to measuring myocardial blood flow in the intact animal, and the method was, therefore, adapted to the dog. This paper details our experiences with the model system and the intact animal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

The Hemodynamic Effects of Drugs on Myocardial Oxygen Use

The circulatory responses to high equinalgesic doses of morphine are compared with those of pethidin. The decrease in mean arterial blood pressure in case of morphine was 28p.c., with a paralleled and identical de­crease in total peripheral resistance and no negative inotropic effects.  Pethidine decreased blood pressure 54p.c., as a result of peripheral vasodilation of 46p.c. and a sharp drop...

متن کامل

Pii: S1010-7940(02)00039-8

Objectives: There has been no method which can measure regional myocardial blood flow in real-time and continuously. The purpose of this study was to validate myocardial blood flow measurement using a thermal diffusion method. For this purpose, myocardial blood flow measurement was performed using the thermal diffusion method and the electrolytic hydrogen clearance method. Methods: Seven pigs w...

متن کامل

Measurement of myocardial blood flow.

This paper represents a review of the recent literature on techniques to measure myocardial blood flow in man. A short discussion on flow meters in followed by a more detailed discussion of the radionuclide techniques used to measure myocardial blood flow. The radionuclide techniques are discussed in two groups: (1) qualitative measurement of blood flow using static images; and (2) quantitative...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005