Effect of Misfit on Preload Maintenance of Retention Screws of Implant-Supported Prostheses
نویسندگان
چکیده
The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implantretention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 lm, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P< 0.05). All groups exhibited significant decrease (P< 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P< 0.05), but there was no statistically significant difference between Groups B and D (P> 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.
منابع مشابه
Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns
The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...
متن کاملEffect of Three Types of Temporary Luting Cements and Abutment Surface Sandblasting on Retentive Strength of Implant-Supported Fixed Prostheses
Background and Aim: Achieving appropriate retention and easy retrieva bility at the same time is challenging in implant-supported fixed par tial dentures (FPDs). Researchers have always been in search of a temporary cement to improve the retentive strength. The aim of this in vitro study was to evaluate the effect of three different temporary ce ments and sandblasting of the abutment surface on...
متن کاملA comparison of preload values in gold and titanium dental implant retaining screws.
This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for...
متن کاملCase Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report
Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...
متن کاملThe Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses.
PURPOSE To examine the effect of different torque application techniques (torqued, retorqued once, and retorqued twice) on the removal torque of implant-supported fixed complete dental prostheses. MATERIALS AND METHODS Four Nobel Biocare implants (4.3 × 13 + 3; 13-mm thread height + 3-mm collar height) were stabilized temporarily inside four holes made in an acrylic mandibular master model. A...
متن کامل