Variability in isopter position and fatigue during semi-automated kinetic perimetry.

نویسندگان

  • Katarzyna Nowomiejska
  • Agnieszka Brzozowska
  • Tomasz Zarnowski
  • Robert Rejdak
  • Richard G Weleber
  • Ulrich Schiefer
چکیده

BACKGROUND Assessment of factors influencing response variability to repeat presentations of III4e stimuli and the fatigue effect during semi-automated kinetic perimetry (SKP). DESIGN Prospective case series; setting: university hospital. PARTICIPANTS 58 patients with severe visual field loss: 21 with glaucoma, 18 with retinitis pigmentosa, and 19 with postchiasmal visual pathway lesions. METHODS Following initial testing with three isopters (I2e or V4e, I4e and III4e), presentations of the III4e stimulus were repeated four times during the same session along identical vectors. MAIN OUTCOME MEASURES Variability in III4e-isopter position (scatter of kinetic threshold) and the difference of isopter area between the first and four subsequent sessions (fatigue effect) of SKP were analyzed by diagnosis, age, visual acuity and reaction time (RT). RESULTS The mean scatter of the kinetic threshold was 2.5 degrees (deg) in the glaucoma group, 1.5 deg in the group with retinitis pigmentosa, and 1.7 deg in the group of patients with postchiasmal lesions. The difference in the isopter area between a single examination and four times repeated examination was 656 square degrees (deg(2)) in the glaucoma group, 104 deg(2) in the retinitis pigmentosa group and 227 deg(2) in the group of patients with postchiasmal lesions. Post-hoc regression analysis revealed that the variability of isopter position increased as the RT increased. CONCLUSION The variability of III4e-isopter positionand fatiguewere most pronounced among glaucoma patients. RT is the most important factor influencing the variability of responses and fatigue during SKP, thus we propose that it can be used as a reliability indicator of SKP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.

Purpose Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods Thirty patients with glaucoma (median...

متن کامل

Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings

PURPOSE To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings. METHODS Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900) using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular ...

متن کامل

Comparison of Automated Kinetic and Static Visual Fields in Neuro-ophthalmology Patients

Eighty-three patients with various neuro-ophthalmic diseases were submitted to a standard automated protocol including kinetic and static perimetry The kinetic protocol included one peripheral, one intermediate and one central isopter and a blind spot contour determination The static protocol included fast thresholding of 80 points within the pericentral field and a 4-2-2-2 foveolar threshold d...

متن کامل

Normal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semiautomated Kinetic Testing on the Octopus 900 Perimeter.

PURPOSE To determine normal values of the visual field (VF), corrected for age and reaction time (RT) for semiautomated kinetic perimetry (SKP) on the Octopus 900 perimeter, create a model describing the age-dependency of these values, and assess test-retest reliability for each isopter. METHODS Eighty-six eyes of 86 ophthalmologically healthy subjects (age 11-79 years, 34 males, 52 females) ...

متن کامل

Volume of visual field assessed with kinetic perimetry and its application to static perimetry

BACKGROUND The purpose of this study was to quantify the volume of the kinetic visual field with a single unit that accounts for visual field area and differential luminance sensitivity. METHODS Kinetic visual field perimetry was performed with a Goldmann perimeter using I4e, I3e, I2e, and I1e targets. The visual fields of 25 normal volunteers (17 women, eight men) of mean age 33.9 ± 10.1 (ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde

دوره 227 3  شماره 

صفحات  -

تاریخ انتشار 2012