Direct thermocouple measurements of temperature rise and heat conduction in the rabbit retina.

نویسندگان

  • H NAJAC
  • B COOPER
  • J H JACOBSON
  • M SHAMOS
  • M BREITFELLER
چکیده

For a given burn, a greater dose was required to raise the temperature to the same level tuhen the spectral distribution of the source included both the visible and the near infrared. Temperature rises compatible with steam production have not been obtained even for very intense burns. In cases of retinal explosion the temperature rose above 40° C, which when added to the body temperature gave a total of about 78° C, sufficient to produce albumin coagulation. Temperature rises 1 or 2 nun. awaij from the center of the burn remained below 2° C. regardless of the intensity of the burn. Direct thermocouple measurements of temperature rise and heat conduction in the rabbit retina

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Deterministic Thermocouple Errors (bias) on the Solution of the Inverse Heat Conduction Problem

This paper demonstrates the deterministic errors in thermocouple measurements, or bias, through numerical simulation and illustrates the impact of these erroneous measurements on inverse heat conduction problem solutions. The case of molten metal solidifying through cooling in a sand mold is considered. Artificial data for the sand surface temperature and at two different locations below the sa...

متن کامل

Effect of Transverse Depressions and Oscillation Marks on Heat Transfer in the Continuous Casting Mold

Results from mathematical models and plant experiments are combined to quantify the effect of transverse depressions and oscillation marks on heat transfer in the continuous casting mold. A heat transfer model has been developed to calculate transient heat conduction within the solidifying steel, coupled with the steady-state heat conduction with the continuous casting mold wall. The model feat...

متن کامل

The thermal pulse decay technique for measuring ultrasonic absorption coefficients

The classic method for measuring absorption coefficients ofmaterials requires adetermination of the temperature rise within a medium during ultrasonic irradiation. Serious errors may result from a viscous heating effect around the required thermocouple probe, and from heat lost by conduction to surrounding, cooler egions. A thermal pulse-decay technique is proposed and evaluated which allows fo...

متن کامل

Inverse Identification of Circular Cavity in a 2D Object via Boundary Temperature Measurements Using Artificial Neural Network

In geometric inverse problems, it is assumed that some parts of domain boundaries are not accessible and geometric shape and dimensions of these parts cannot be measured directly. The aim of inverse geometry problems is to approximate the unknown boundary shape by conducting some experimental measurements on accessible surfaces. In the present paper, the artificial neural network is used to sol...

متن کامل

Determination of Absolute Sound Levels and Acoustic Absorption Coefficients by Thermocouple Probes--Theory

A detailed theoretical analysis of the operation of thermocouple probes used to determine absolute sound levels or acoustic absorption coefficients is presented. The probe consists of a thermocouple imbedded in a sound absorbing medium which closely matches in density and sound velocity the medium in which the sound level is to be determined. In use the transducer which generates the acoustic f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 2  شماره 

صفحات  -

تاریخ انتشار 1963