Nonlinear derating of high-intensity focused ultrasound beams using Gaussian modal sums.

نویسندگان

  • Seyed Ahmad Reza Dibaji
  • Rupak K Banerjee
  • Joshua E Soneson
  • Matthew R Myers
چکیده

A method is introduced for using measurements made in water of the nonlinear acoustic pressure field produced by a high-intensity focused ultrasound transducer to compute the acoustic pressure and temperature rise in a tissue medium. The acoustic pressure harmonics generated by nonlinear propagation are represented as a sum of modes having a Gaussian functional dependence in the radial direction. While the method is derived in the context of Gaussian beams, final results are applicable to general transducer profiles. The focal acoustic pressure is obtained by solving an evolution equation in the axial variable. The nonlinear term in the evolution equation for tissue is modeled using modal amplitudes measured in water and suitably reduced using a combination of "source derating" (experiments in water performed at a lower source acoustic pressure than in tissue) and "endpoint derating" (amplitudes reduced at the target location). Numerical experiments showed that, with proper combinations of source derating and endpoint derating, direct simulations of acoustic pressure and temperature in tissue could be reproduced by derating within 5% error. Advantages of the derating approach presented include applicability over a wide range of gains, ease of computation (a single numerical quadrature is required), and readily obtained temperature estimates from the water measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

An exposimetry system using tissue-mimicking liquid.

Acoustic output measurements of diagnostic ultrasound scanners are currently performed in water and derated to approximate in situ values. The derating scheme ignores nonlinear propagation of sound waves and has been shown in previous numerical and experimental studies to tend to underestimate relevant pressure and intensity values in tissue mimicking media. This work describes an alternative m...

متن کامل

Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma < 1) or strong waves (Gamma >...

متن کامل

Pii: S0301-5629(02)00610-5

Because the number of applications for medical ultrasonic devices continue to increase and, hence, the number of diagnostic ultrasound (US) systems increase, there is a need to reliably characterize the sources in terms of their output pressures. Currently, the transducers are characterized by making pressure measurements in water for every voltage range applied to the source and, then, linearl...

متن کامل

Interaction of high intensity focused ultrasound with biological materials

This work is motivated by possible medical applications of focused ultrasound in minimally invasive treatment of a variety of disorders. The mechanical and thermal effects caused by high-frequency ultrasound in different material systems are calculated using a finite element based program called PZflex. The pressure distributions generated by plane as well as focused ultrasound beams are presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 134 5  شماره 

صفحات  -

تاریخ انتشار 2013