Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

نویسندگان

  • Ciprian Catana
  • Yibao Wu
  • Martin S Judenhofer
  • Jinyi Qi
  • Bernd J Pichler
  • Simon R Cherry
چکیده

UNLABELLED PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. RESULTS PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. CONCLUSION The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative carotid MR/PET imaging: comprehensive comparison of MRAC and CTAC attenuation maps in MR/PET emission data and PET/CT

Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, NY, NY, USA Current MR/PET systems employ segmentation of MR images and subsequent assignment of empirical attenuation map values for quantitative PET reconstruction. In this current study we examine the quantitative differences between our carotid artery imaging protocol on both a PET/CT and an MR/PET scann...

متن کامل

Simultaneous trimodal PET-MR-EEG imaging: Do EEG caps generate artefacts in PET images?

Trimodal simultaneous acquisition of positron emission tomography (PET), magnetic resonance imaging (MRI), and electroencephalography (EEG) has become feasible due to the development of hybrid PET-MR scanners. To capture the temporal dynamics of neuronal activation on a millisecond-by-millisecond basis, an EEG system is appended to the quantitative high resolution PET-MR imaging modality alread...

متن کامل

MR-based PET Attenuation Correction for Neurological Studies Using Dual-Echo UTE Sequences

INTRODUCTION Due to the limited space available inside an MR scanner, most of the MR compatible PET inserts are not equipped with a transmission source, which makes the implementation and validation of an MR-based attenuation correction (AC) method necessary. The obvious challenge is that MR images are not typically directly related to tissue linear attenuation coefficients (LACs). Furthermore,...

متن کامل

Hybrid PET/MRI of intracranial masses: initial experiences and comparison to PET/CT.

UNLABELLED Simultaneous PET and MRI using new hybrid PET/MRI systems promises optimal spatial and temporal coregistration of structural, functional, and molecular image data. In a pilot study of 10 patients with intracranial masses, the feasibility of tumor assessment using a PET/MRI system comprising lutetium oxyorthosilicate scintillators coupled to avalanche photodiodes was evaluated, and qu...

متن کامل

Validation of a simultaneous PET/MR system model for PET simulation using GATE

LaTIM UMR 1101, Brest, France Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 2006