Method for characterization of material loss from modular head-stem taper surfaces of hip replacement devices

نویسندگان

  • Radu Racasan
  • Paul Bills
  • Liam Blunt
  • Alister Hart
  • John Skinner
چکیده

Assessment of the head-stem taper junction requires the estimation of material loss from the taper surfaces of both femoral head and stem. This paper describes a method for the measurement and analysis of material loss from the modular taper junction of hip replacements, in particular femoral stem tapers where generally the entire taper surface has been engaged. In such cases no direct unengaged datum surface is readily identifiable to assess material loss. The highly anisotropic topology of some stem designs poses additional challenges to the measurement and analysis process. Estimation of material loss of retrieved femoral stems is further complicated by retrieval damage or surface deposits often present on the taper surface. The femoral head tapers typically exhibit areas of pristine surface attributed to the difference in taper length compared to the engaging stem. These areas can be selected as unworn when employed in the analysis process, provided they do not show surface damage or deposits. Measurement of the taper surfaces has been performed using a Talyrond (Ametek, Inc., US) outof-roundness measurement instrument equipped with a 5μm diamond tip stylus. Vertical axial traces were employed to digitize the surface of the taper. Measurement data has been analyzed using a multi stage process that has been specifically adapted for stem tapers. The underlying stem taper geometry is determined by means of a morphological filter applied to the high aspect ratio microstructure. This paper presents a study of 40 retrieved LHMoM hip replacements that have been analyzed to ascertain the material loss at the modular taper junction. The purpose of this study was to ascertain the viability of characterizing material loss from the stem taper junction and to provide insight into the overall material loss contribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements.

It has been speculated that material loss, either as corrosion or wear, at the head-stem taper junction is implicated in the high revision rates reported for metal-on-metal total hip replacements. We measured the volume of material loss from the taper and bearing surfaces of retrieved devices, and investigated the associations with blood metal ion levels and the diagnosis of a cystic or solid p...

متن کامل

Assessing the material loss of the modular taper interface in retrieved metal on metal hip replacements

Measuring the amount of material loss in the case of revised hip replacements is considered to be a prerequisite of understanding and assessing the true in vivo performance of the implant. This paper outlines a method developed by the authors for quantifying taper material loss as well as more general taper interface parameters. Previous studies have mostly relied on visual inspection to assess...

متن کامل

Primary hip replacement stem taper fracture due to corrosion in 3 patients

© 2016 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) DOI 10.3109/17453674.2015.1128780 (McGrory et al. 2015, Bishop et al. 2013). No mechanical implant failures (i.e. fractures) have b...

متن کامل

Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine.

In contrast to the articulating and taper surfaces of failed total hip replacements, volumetric wear analysis of trunnions is not routinely performed. Metal wear particles from the trunnion may contribute not only to the failures of metal-on-metal total hip replacements but also to all hip replacements utilising metal trunnions. A validation study was performed with the material removed in stag...

متن کامل

A combined experimental and finite element approach to analyse the fretting mechanism of the head–stem taper junction in total hip replacement

Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental loading conditions to reproduce clinically relevant fretting corrosion features observed in retrieved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016