Thoracoscopic patch insulation to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy.

نویسندگان

  • Neeraj Mediratta
  • Diane Barker
  • James McKevith
  • Peter Davies
  • Sandra Belchambers
  • Archana Rao
چکیده

AIMS Cardiac resynchronization therapy is an established therapy for heart failure, improving quality of life and prognosis. Despite advances in technique, available leads and delivery systems, trans-venous left ventricular (LV) lead positioning remains dependent on the patient's underlying venous anatomy. The left phrenic nerve courses over the surface of the pericardium laterally and may be stimulated by the LV pacing lead, causing uncomfortable diaphragmatic twitch. This paper describes a video-assisted thoracoscopic (VATS) procedure to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy. METHODS AND RESULTS Most current ways of avoiding phrenic stimulation involve either electronic reprogramming to distance the phrenic nerve from the stimulation circuit or repositioning the lead. We describe a case where the phrenic nerve was surgically insulated from the stimulating current by insinuating a patch of bovine pericardium between the epicardium and native pericardium of the heart thus completely resolving previously intolerable and incessant diaphragmatic twitch. The procedure was performed under general anaesthesia with single-lung ventilation and minimal use of neuromuscular blocking agents. Surgical patch insulation of the phrenic nerve was performed using minimally invasive VATS surgery, as a short-stay procedure, with no complications. No diaphragmatic twitch occurred post-surgery and the patient continued to gain symptomatic benefit from cardiac synchronization therapy (New York Heart Association Class III to II), enabling return to work. CONCLUSIONS In cases where the trans-venous position of a LV lead is limited by troublesome phrenic nerve stimulation, thoracoscopic surgical patch insulation of the phrenic nerve could be considered to allow beneficial cardiac resynchronization therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead.

INTRODUCTION Epicardial cardiac resynchronization therapy (CRT) permits unrestricted electrode positioning. However, this requires surgical placement of device leads and the risk of unwanted phrenic nerve stimulation. We hypothesized that shielded electrodes can capture myocardium without extracardiac stimulation. METHODS In 6 dog and 5 swine experiments, we used a percutaneous approach to ac...

متن کامل

Simple and effective solution for diaphragm pacing by that uses the transvenous femoral approach in a patient treated with cardiac resynchronization-defibrillator therapy: The wrapping method

The use of cardiac resynchronization therapy (CRT) has become widespread in patients with heart failure who meet the criteria for implantation. Coronary sinus lead positioning is important to provide the intended biventricular stimulation. Diaphragm pacing is a lead-related complication which occurs secondary to phrenic nerve stimulation. We present the case of a 58-year-old male patient who ha...

متن کامل

A novel approach to detect phrenic nerve stimulation in cardiac resynchronization therapy.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A novel approach to detect phrenic nerve stimulatio...

متن کامل

Diaphragmatic stimulation caused by cardiac resynchronization treatment.

A 69-year-old man with a history of severe nonischemic cardiomyopathy managed with a cardiac resynchronization-defibrillator presented to the outpatient clinic with uncomfortable pulsation over the left upper-abdominal area when lying on his left side. He was hemodynamically stable. When he was recumbent in a left-lateral position, there were visible and palpable contractions of the left upper-...

متن کامل

Quadripolar Left Ventricular Lead in a Patient with CRT-D Does Not Overcome Phrenic Nerve Stimulation

Effective cardiac resynchronization therapy (CRT) requires an accurate atrio-biventricular pacing system. The innovative Quartet lead is a quadripolar, over-the-wire left ventricular lead with four electrodes and has recently been designed to provide more options and greater control in pacing vector selection. A lead with multiple pacing electrodes is a potential alternative to physical adjustm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 7  شماره 

صفحات  -

تاریخ انتشار 2012