Incidence of embolism and paravalvar leak after St Jude Silzone valve implantation: experience from the Cardiff Embolic Risk Factor Study.

نویسندگان

  • A Ionescu
  • N Payne
  • A G Fraser
  • J Giddings
  • G L Grunkemeier
  • E G Butchart
چکیده

BACKGROUND Silver coating of the sewing ring (Silzone) was introduced as a modification of the St Jude Medical standard valve to provide antibacterial protection, but the valve has recently been withdrawn. OBJECTIVE To study patients with these prostheses to assess possible adverse effects, and to guide their follow up. DESIGN Prospective observational study of risk factors for stroke after valve replacement. SETTING Cardiology and cardiac surgery departments in a tertiary centre. PATIENTS There were 51 patients with Silzone and 116 with St Jude Medical standard valves. Patients undergoing aortic valve replacement were well matched for stroke risk factors. Silzone patients with mitral valve replacement were younger (mean (SD) age 61 (10) v 66 (7) years), more likely to be female (95% v 65%), and had more pulmonary arterial hypertension (100% v 78%), but fewer coronary artery bypass grafts (5% v 33%) than patients with standard mitral valve replacements (all p < 0.05). RESULTS Follow up was 100% in the Silzone group (mean duration 3.0 (0.9) years) and 97.4% in the standard group (4.7 (1.4) years). Survival, morbidity, and anticoagulant control were documented over 682 follow up years (153 for Silzone and 529 for standard). There were six embolic strokes and one peripheral embolism in the Silzone group, all within three months after operation, and five embolic strokes and one peripheral embolism in the standard group. Freedom from major thromboembolism at three months was 65% in the Silzone mitral valve replacement group and 100% in the standard mitral valve replacement group (difference 35%, 95% confidence interval 8% to 62%). There was one reoperation for paravalvar leak in the standard group, but none in the Silzone group (NS). Anticoagulant control in the two groups was similar. CONCLUSIONS Patients with Silzone mitral valves had a high rate of early postoperative embolism but no excess paravalvar leak.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INTERVENTIONAL CARDIOLOGY AND SURGERY Incidence of embolism and paravalvar leak after St Jude Silzone valve implantation: experience from the Cardiff Embolic Risk Factor Study

Background: Silver coating of the sewing ring (Silzone) was introduced as a modification of the St Jude Medical standard valve to provide antibacterial protection, but the valve has recently been withdrawn. Objective: To study patients with these prostheses to assess possible adverse effects, and to guide their follow up. Design: Prospective observational study of risk factors for stroke after ...

متن کامل

The Silzone effect: how to reconcile contradictory reports?

OBJECTIVE To attempt to reconcile reports containing contradictory findings with the St. Jude Medical Silzone heart valve. METHODS Major leak and thromboembolism data were extracted from available Silzone valve studies. Linearized rates were used to summarize and compare the events rates among the studies. RESULTS The Artificial Valve Endocarditis Reduction Trial (AVERT) study reported sign...

متن کامل

Outcome of patients treated with a St. Jude prosthetic heart valve.

BACKGROUND Long-term outcome of patients treated with a St. Jude prosthetic heart valve was reported by investigators in Lausanne, Switzerland. This article quantifies the mortality and morbidity implications of single or multiple heart valve replacement. RESULTS After hospital discharge, mortality ratios were highest for duration 5-10 years, roughly comparable in patients who received a sing...

متن کامل

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging.

OBJECTIVES The aim of this study was prospective investigation of silent and clinically apparent cerebral embolic events and neurological impairment after transfemoral aortic valve implantation (TAVI). BACKGROUND TAVI is a novel therapeutic approach for multimorbid patients with severe aortic stenosis. We investigated peri-interventional cerebral embolism with diffusion-weighted magnetic reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 89 9  شماره 

صفحات  -

تاریخ انتشار 2003