SCIENTIFIC REPORT Ophthalmodynamometric determination of the central retinal vessel collapse pressure correlated with systemic blood pressure

نویسنده

  • J B Jonas
چکیده

Aims: To evaluate whether determination of the central retinal artery and vein collapse pressure correlate with systemic blood pressure measurements, using a new Goldmann contact lens associated ophthalmodynamometric device Methods: The prospective clinical study included 92 eyes of 92 patients presenting with cataract or refractive problems (n = 40; control study group) or with retinal and orbital pathologies (n = 52). With topical anaesthesia, a Goldmann contact lens fitted with a pressure sensor in its holding ring was placed onto the cornea. Pressure was asserted onto the globe by pressing the contact lens, and the pressure value at the time when the central retinal artery and vein started pulsating were noted as central retinal artery and vein collapse pressure. Additionally, the brachial arterial blood pressure was measured. Results: In the control study group, central retinal artery collapse pressure was highly significantly correlated with diastolic blood pressure (correlation coefficient r = 0.77; p,0.001) and systolic blood pressure (r = 0.35; p = 0.03). Central retinal vein collapse pressure was statistically independent of diastolic blood pressure (p = 0.11). In eyes with retinal or orbital diseases, the correlation coefficients were lower than in the control study group. In eyes with retinal arterial occlusions, central retinal vessel collapse pressure measurements were not correlated with arterial blood pressure measurements. Conclusions: Depending on coexisting retinal or orbital diseases, ophthalmodynamometric estimation of the central retinal artery collapse pressure, performed during a routine Goldmann contact lens ophthalmoscopy, correlates with systemic blood pressure measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ophthalmodynamometric determination of the central retinal vessel collapse pressure correlated with systemic blood pressure.

AIMS To evaluate whether determination of the central retinal artery and vein collapse pressure correlate with systemic blood pressure measurements, using a new Goldmann contact lens associated ophthalmodynamometric device METHODS The prospective clinical study included 92 eyes of 92 patients presenting with cataract or refractive problems (n = 40; control study group) or with retinal and orb...

متن کامل

Reproducibility of ophthalmodynamometric measurements of central retinal artery and vein collapse pressure.

BACKGROUND To assess the reproducibility of ophthalmodynamometric measurements using a new, Goldmann contact lens associated, device allowing biomicroscopic visualisation of the optic disc. METHODS The prospective clinical study included 87 eyes of 58 subjects presenting with a normal fundus (n=40), or ocular diseases (n=47). With topical anaesthesia, a Goldmann contact lens, fitted with a pr...

متن کامل

Relation between pressure determined by ophthalmodynamometry and aortic pressure in the dog.

AIMS Ophthalmodynamometry has been used extensively since the last century; however, controversy surrounds what it actually measures. This study was set up to determine the relation between ophthalmodynamometric (ODP) and systemic blood pressures. METHODS Aortic pressure was continuously monitored and altered by phlebotomy in six anaesthetised dogs, while ophthalmodynamometry was performed, b...

متن کامل

Central retinal artery and vein collapse pressure in eyes with chronic open angle glaucoma.

AIMS To determine central retinal vessel collapse pressure in chronic open angle glaucoma. METHODS For 19 eyes with chronic open angle glaucoma and 27 eyes of a control group, central retinal vessel collapse pressure was measured by a Goldmann contact lens fitted with a pressure sensor in its holding grip. RESULTS Central retinal vein collapse pressure was significantly (p=0.001) higher in ...

متن کامل

Occlusive thromboaortopathy (Takayasu's disease): cervical arterial stenoses, retinal arterial pressure, retinal microaneurysms and prognosis.

Eighty-one young Japanese patients with occlusive thromboaortopathy (Takayasu's disease) were classed into three groups according to the degree and extent of diameter stenosis in the 4 cervical arterial systems, as determined by serial aortography. Class I was made up of 63 patients with 70% or greater stenosis in less than 3 systems, including 33 patients without systemic hypertension (Class I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004