Ultra-high-pressure balloon angioplasty for treatment of resistant stenoses within or adjacent to previously implanted pulmonary arterial stents.

نویسندگان

  • Jessica Maglione
  • Lisa Bergersen
  • James E Lock
  • Doff B McElhinney
چکیده

BACKGROUND Stents are essential tools in the management of pulmonary arterial (PA) stenosis in patients with congenital heart disease. Although stents can usually be reexpanded as children grow, resistant in-stent or peri-stent obstruction can complicate the management of PA stents. Angioplasty with ultra-high-pressure (UHP) balloons may facilitate successful treatment of stent-associated PA stenoses that are resistant to high-pressure dilation. METHODS AND RESULTS We reviewed patients who underwent UHP angioplasty of in-stent or peri-stent PA stenoses that were resistant to high-pressure redilation. A resistant stenosis was defined as a residual balloon waist during high-pressure redilation of the stent, along with a pressure gradient and/or angiographic stenosis. Thirty-four lesions in 29 patients, including 8 with multiple concentric, overlapping, or adjacent stents, were included. The median age at UHP angioplasty was 9 years, and a median of 4 years had elapsed since unsuccessful high-pressure angioplasty. Thirty-one of the 34 (91% [81% to 100%]) UHP angioplasty procedures were successful in relieving the resistant stenosis. Balloon:waist diameter ratios were conservative (median 1.26), reflecting the ability of UHP balloons to "fracture" nearly all obstructions. After UHP dilation, lesion diameter increased by a median of 3.1 mm (36%), significantly more than after previous high-pressure dilation (1.3 mm, 19%; P<0.001). In 5 lesions, UHP angioplasty fractured the stent, allowing further vessel expansion. There were no vascular or other complications. CONCLUSIONS UHP angioplasty was safe and effective for treatment of stent-related resistant PA stenosis in this series; the ability to fracture maximally expanded stents may extend the utility of stents in the pediatric population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-High-Pressure Balloon Angioplasty for Treatment of Resistant Stenoses Within or Adjacent to Previously Implanted Pulmonary Arterial Stents Brief title: Ultra-high pressure redilation of PA stents

Background. Stents are essential tools in the management of pulmonary arterial (PA) stenosis in patients with congenital heart disease. Although stents can usually be reexpanded as children grow, resistant instent or peri-stent obstruction can complicate the management of PA stents. Angioplasty with ultra-highpressure (UHP) balloons may facilitate successful treatment of stent-associated PA ste...

متن کامل

Intentional Fracture of Maximally Dilated Balloon-Expandable Pulmonary Artery Stents Using Ultra-High-Pressure Balloon Angioplasty: A Preliminary Analysis.

BACKGROUND Treatment with endovascular stents has become increasingly common for the management of vascular stenosis in congenital heart disease. The use of stents in smaller patients has been tempered by concerns about the potential for stent expansion to accommodate somatic growth. One solution to limited stent diameter is the intentional fracture of maximally dilated stents, which can be acc...

متن کامل

Stent Implantation in Congenital Heart Disease: A New Therapeutic Modality

Vascular stenoses and hypoplasia in children are often associated with congenital heart disease or occur as a residual lesion or complications after surgical repair. Among these lesions, branch pulmonary artery stenoses are the commonest, other lesions include coarctation of aorta, stenosis of systemic veins after Fontan repairs, post-operative pulmonary venous stenosis, aortopulmonary collater...

متن کامل

Using 6-mm Cutting Balloon angioplasty in patients with resistant peripheral artery stenosis: preliminary results.

OBJECTIVE The objective of this study was to assess the efficacy of 6-mm Cutting Balloon angioplasty in patients with resistant peripheral stenoses caused by neointimal hyperplasia or irradiation-induced arteriopathy in vascular territories that are not amenable for use of the smaller Cutting Balloons that are used in cardiology. CONCLUSION Peripheral Cutting Balloon angioplasty with the new ...

متن کامل

Percutaneous treatment of stenosed major aortopulmonary collaterals with balloon dilatation and stenting: what can be achieved?

BACKGROUND The natural history of major aortopulmonary collateral arteries (MAPCAs) in patients with pulmonary atresia and ventricular septal defect (PA-VSD) is frequently complicated by progressive stenosis, leading to pulmonary hypoperfusion and debilitating hypoxaemia. OBJECTIVE To evaluate balloon dilatation and stenting for relief of stenoses and improvement of pulmonary flow in patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2009