Fixation-free assessment of the Hirschberg ratio.
نویسندگان
چکیده
PURPOSE To describe a novel methodology by which to measure the Hirschberg ratio (HR) in infants. The methodology does not require fixation on specific points, and measurements are made while infants look naturally at a display. METHODS The HR is calculated automatically from measurements of the direction of the optical axis, the position of the pupil center, and corneal reflexes in video images from an advanced two-camera eye-tracking system. The performance of the novel fixation-free procedure (FFP) was evaluated in 43 adults by measuring the average difference and the 95% limits of agreement with the standard fixation-based procedure (FBP). Repeatability of the HR measurements was evaluated by assessing the 95% limits of agreement between two independent measurements. Performance of the FFP was also evaluated in five infants. RESULTS In adults, the average HR was 12.89 +/- 1.22 degrees/mm for FFP and 12.81 +/- 1.22 degrees/mm for FBP. FFP and FBP measurements were highly correlated (r = 0.95; P < 0.001). The 95% limits of agreement between FFP and FBP were +/-0.86 degrees/mm. The 95% limits of agreement of repeated measurements were +/-0.66 degrees/mm for FFP and +/-0.77 degrees/mm for FBP. In infants, the 95% limits of agreement of repeated measurements by FFP were +/-0.63 degrees/mm. CONCLUSIONS In adults, the FFP provides accurate measurements of the HR that are in excellent agreement with measurements by FBP. In infants, measurements of HR by FFP show the same repeatability and consistency.
منابع مشابه
Measurement of binocular alignment in normal monkeys and in monkeys with strabismus.
Accurate assessment of ocular alignment in monkeys is difficult because typical clinical methods require extensive cooperation by the subject or provide only a rough estimate of the misalignment. Recently, Brodie derived a geometrical model for determining the Hirschberg ratio in humans, and validated it photographically. In this study, we have applied these procedures in order to determine cor...
متن کاملFlow Cytometry: A New Approach for Indirect Assessment of Sperm Protamine Deficiency
Background Flow cytometry (FCM) has been extensively used to study mammalian sperm in the areas of clinical andrology and reproductive toxicology. FCM provides a powerful advantage over microscopy technique in terms of rapid accurate and reproducible technology for the quantification of various cell characteristics including chromatin status. During spermiogenesis histones are replaced by prota...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملCalibration of the Hirschberg test in human infants.
PURPOSE The Hirschberg ratio has been defined as the ratio of the change in angular position of the line of sight to the change in location of the first Purkinje image relative to the pupil center. This study was designed to determine empirically whether the adult value of the Hirschberg ratio (approximately 22 prism diopters/mm) is a suitable value to use for all ages. Because many structures ...
متن کاملThe reliability of a video-enhanced Hirschberg test under clinical conditions.
PURPOSE To examine the reliability and usefulness of a video-based Hirschberg test under clinical conditions. METHODS The authors estimated ocular deviation in 87 patients with strabismus through automated analysis of corneal reflex displacement using a video refractor. The reproducibility of measurement, the comparison with the prism and alternate cover test (PACT), and the distribution of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 8 شماره
صفحات -
تاریخ انتشار 2010