5-year clinical outcomes after sirolimus-eluting stent implantation insights from a patient-level pooled analysis of 4 randomized trials comparing sirolimus-eluting stents with bare-metal stents.
نویسندگان
چکیده
OBJECTIVES Five-year clinical follow-up has been scheduled per protocol by the 4 Cypher (Cordis/Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) versus bare-metal stent (BMS) randomized trials. BACKGROUND A delayed arterial healing response after drug-eluting stent implantation has raised concerns about the long-term safety of drug-eluting stents. METHODS In a pooled analysis of 4 randomized trials, 1,748 patients were assigned to receive either an SES (n = 878) or BMS (n = 870). RESULTS At 5 years, there was no significant difference in the rate of death, myocardial infarction (MI), or the composite of death/MI between the 2 groups (15.1% in the SES group vs. 13.6% in the BMS group; p = 0.36). The 5-year incidence of stent thrombosis by the Academic Research Consortium definition did not differ between SES and BMS (definite/probable stent thrombosis, 2.1% vs. 2.0%; p = 0.99). The incidence of very late stent thrombosis was also similar between the SES and BMS groups (1.4% vs. 0.7%; p = 0.22). The annualized rates of definite/probable stent thrombosis after 1 year were 0.4% for SES and 0.2% for BMS. The 5-year incidence of target vessel revascularization was significantly lower in the SES group (15.2% vs. 30.1%; p < 0.0001). CONCLUSIONS In this patient-level pooled analysis, overall use of SES compared with BMS demonstrated persistent superior efficacy at 5 years in terms of a reduction in target vessel revascularization, without an increase in rates of death, MI, or stent thrombosis. (The Initial Double-Blind Drug-Eluting Stent vs Bare-Metal Stent Study, NCT00233805; The Study of the BX Velocity Stent in the Treatment of De Novo Artery Lesions, NCT00381420; Study of Sirolimus-Coated BX VELOCITY Balloon-Expandable Stent in Treatment of de Novo Native Coronary Artery Lesions [SIRIUS], NCT00232765; The Study of the BX VELOCITY Stent In Patients With De Novo Coronary Artery Lesions, NCT00235144).
منابع مشابه
A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents.
BACKGROUND Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been questioned recently. METHODS We performed a pooled analysis of 1748 patients in four randomized trials evaluating...
متن کاملSafety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.
BACKGROUND The safety of drug-eluting stents has been called into question by recent reports of increased stent thrombosis, myocardial infarction, and death. Such studies have been inconclusive because of their insufficient size, the use of historical controls, a limited duration of follow-up, and a lack of access to original source data. METHODS We performed a pooled analysis of data from fo...
متن کاملImpact of sirolimus-eluting stents on outcome in diabetic patients: a SIRIUS (SIRolImUS-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo coronary artery lesions) substudy.
BACKGROUND Randomized clinical trials have shown that a sirolimus-eluting stent significantly reduces restenosis after percutaneous coronary revascularization. Diabetic patients are known to have a higher risk of restenosis compared with nondiabetic patients. The purpose of this analysis was to determine the impact of sirolimus-eluting stents on outcomes of diabetic compared with nondiabetic pa...
متن کاملAnalysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents.
BACKGROUND The long-term effects of treatment with sirolimus-eluting stents, as compared with bare-metal stents, have not been established. METHODS We performed an analysis of individual data on 4958 patients enrolled in 14 randomized trials comparing sirolimus-eluting stents with bare-metal stents (mean follow-up interval, 12.1 to 58.9 months). The primary end point was death from any cause....
متن کاملLate thrombosis of drug-eluting stents: a meta-analysis of randomized clinical trials.
PURPOSE Drug-eluting stents are commonly used for percutaneous coronary intervention. Despite excellent clinical efficacy, the association between drug-eluting stents and the risk for late thrombosis remains imprecisely defined. METHODS We performed a meta-analysis on 14 contemporary clinical trials that randomized 6675 patients to drug-eluting stents (paclitaxel or sirolimus) compared with b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 54 10 شماره
صفحات -
تاریخ انتشار 2009