A smog chamber comparison of a microfluidic derivatisation measurement of gas-phase glyoxal and methylglyoxal with other analytical techniques

نویسندگان

  • X. Pang
  • A. C. Lewis
  • A. R. Rickard
  • M. T. Baeza-Romero
  • T. J. Adams
  • S. M. Ball
  • M. J. S. Daniels
  • I. C. A. Goodall
  • P. S. Monks
  • S. Peppe
  • M. Ródenas García
  • P. Sánchez
چکیده

A microfluidic lab-on-a-chip derivatisation technique has been developed to measure part per billion (ppbV) mixing ratios of gaseous glyoxal (GLY) and methylglyoxal (MGLY), and the method is compared with other techniques in a smog chamber experiment. The method uses o(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) as a derivatisation reagent and a microfabricated planar glass micro-reactor comprising an inlet, gas and fluid splitting and combining channels, mixing junctions, and a heated capillary reaction microchannel. The enhanced phase contact area-to-volume ratio and the high heat transfer rate in the micro-reactor resulted in a fast and highly efficient derivatisation reaction, generating an effluent stream ready for direct introduction to a gas chromatograph-mass spectrometer (GC-MS). A linear response for GLY was observed over a calibration range 0.7 to 400 ppbV, and for MGLY of 1.2 to 300 ppbV, when derivatised under optimal reaction conditions. The analytical performance shows good accuracy (6.6 % for GLY and 7.5 % for MGLY), suitable precision (<12.0 %) with method detection limits (MDLs) of 75 pptV for GLY and 185 pptV for MGLY, with a time resolution of 30 min. These MDLs are below or close to typical concentrations of these compounds observed in ambient air. The feasibility of the technique was assessed by applying the methodology to quantify α-dicarbonyls formed during the photo-oxidation of isoprene in the EUPHORE chamber. Good correlations were found between microfluidic measurements and Fourier Transform InfraRed spectroscopy (FTIR) with a correlation coefficient (r2) of 0.84, Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) (r2 = 0.75), solid phase micro extraction (SPME) (r2 = 0.89), and a photochemical chamber box modelling calculation (r2 = 0.79) for GLY measurements. For MGLY measurements, the microfluidic technique showed good agreement with BBCEAS (r2 = 0.87), SPME (r2 = 0.76), and the modeling simulation (r2 = 0.83), FTIR (r2 = 0.72) but displayed a discrepancy with Proton-Transfer Reaction Timeof-Flight Mass Spectrometry (PTR-ToF-MS) with r2 value of 0.39. Published by Copernicus Publications on behalf of the European Geosciences Union. 374 X. Pang et al.: A microfluidic derivatisation measurement of glyoxal and methylglyoxal

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrogen Peroxide, Organic Peroxides and Higher Carbonyl Compounds Determined during the BERLIOZ Campaign

Gas-phase H2O2, organic peroxides and carbonyl compounds were determined at various sites from Mid-July to early August 1998 during the BERLIOZ campaign in Germany. The sites were located northwest of Berlin and were chosen to determine pollutants downwind of the city emissions during a summer smog episode. Hydrogen peroxide (H2O2), methyl hydroperoxide (MHP, CH3OOH) and occasionally hydroxymet...

متن کامل

اثر یک ماه تیمار با سیستئین بر وضعیت قند و لیپید، همچنین گلیکه و اکسید‌ شدنLDL در رت مدل دیابتی ـ آتروسکلروزی

Background: Diabetes is the most common metabolic diseases and its vascular complications are main cause of death in diabetic patients. Patients with hyperglycemia, dyslipidemia and oxidative stress are prone to diabetes complications. The goal of this study was investigation of the effect of cysteine (Cys) on hyperglycemia, lipid profile, atherogenic index, glyoxal, methylglyoxal, oxidative st...

متن کامل

Chamber studies of secondary organic aerosol growth by reactive uptake of simple carbonyl compounds

[1] Recent experimental evidence indicates that heterogeneous chemical reactions play an important role in the gas-particle partitioning of organic compounds, contributing to the formation and growth of secondary organic aerosol in the atmosphere. Here we present laboratory chamber studies of the reactive uptake of simple carbonyl species (formaldehyde, octanal, trans,trans-2,4-hexadienal, glyo...

متن کامل

Characterisation and optimisation of a sample preparation method for the detection and quantification of atmospherically relevant carbonyl compounds in aqueous medium

Carbonyl compounds are ubiquitous in the atmosphere and either emitted primarily from anthropogenic and biogenic sources or they are produced secondarily from the oxidation of volatile organic compounds. Despite a number of studies about the quantification of carbonyl compounds a comprehensive description of optimised methods is scarce for the quantification of atmospherically relevant carbonyl...

متن کامل

A Modelling System for Mechanism Evaluation Using Chamber Data

Gas-phase chemical mechanisms for use in regional or global tropospheric atmospheric chemistry applications require validation against measurement data in order to assure the modeller and policy-makers that the mechanism adequately represents the chemical processes of the real atmosphere. One means of mechanism validation is through the use of smog-chamber data, in which atmospheric chemistry e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014