Microbubbles detection during cardiopulmonary bypass with transoesophageal echocardiography: a case report
نویسندگان
چکیده
INTRODUCTION Microembolic signals are usually detected with transcranial doppler during cardiac surgery.This report focuses on suggesting the transesophageal echocardiography as a different diagnostic approach to detect microemboli during cardiopulmonary bypass. CASE PRESENTATION A 58 year old male patient, caucasian race, was operated on video assisted minimally invasive mitral valve repair using right minithoracotomy approach. His past medical history included an uncontrolled hypertension, dyslipidemia, insulin dependent diabetes mellitus, carotid arteries stenosis. The extracorporeal circulation was performed with femoral-femoral artery and venous approach. Negative pressure for vacuum assist venous drainage was applied in order to facilitate venous blood return. The patient had a brain monitoring with bilateral transcranial doppler of middle cerebral arteries and a double channels electroencephalogram. A three dimensional transesophageal echocardiography to evaluate the mitral valve repair was performed.During the cardiopulmonary bypass a significant microembolic activity was detected in the middle cerebral arteries spectrum velocities due to gas embolism from venous return. Simultaneous recording of microbubbles was also observed on the descending thoracic aorta transesophageal echo views. CONCLUSION During the aortic cross-clamping time the transesophageal echocardiography can be useful as an alternative method to assess the amount of gas embolism coming from cardiopulmonary bypass. These informations can promote immediate interaction between perfusionist, surgeon and anesthesiologist to perform adequate manoeuvres in order to reduce the microembolism during extracorporeal circulation.
منابع مشابه
Contrast echocardiography: a method to visualize changes in regional myocardial perfusion in the dog model for CABG surgery.
The ability of contrast echocardiography to assess regional myocardial perfusion during cardiopulmonary bypass in a dog model for coronary artery bypass surgery was evaluated. Sonicated Renograffin-76 microbubbles (meglumin diatrigoate and sodium diatrigoate) were injected into an aortic root proximal to an aortic occlusion clamp root while dogs were on cardiopulmonary bypass, with the heart ar...
متن کاملTransoesophageal echocardiography reduces invasiveness of cavoatrial tumour thrombectomy
The traditional approach to cavoatrial thrombus excision requires median sternotomy, cardiopulmonary bypass with or without hypothermia and circulatory arrest and is associated with significant morbidity and mortality. We describe a transoesophageal echocardiography guided balloon catheter assisted technique for cavoatrial thrombectomy that avoids thoracotomy, extracorporeal circulation and cir...
متن کاملEchocardiographic detection of left atrial mobile calcium debris of trido valve surgery: a case report
Calcification of the cardiac chambers is among the challenges associated with reoperative cardiac surgeries by increasing the risk of systemic embolization. We experienced a case of an unexpected detected mass by intraoperative transesophageal echocardiography during weaning from cardiopulmonary bypass in a patient undergoing trido mitral and tricuspid valve replacement surgery. The surgically ...
متن کاملFormation of intracardiac thrombus during cardiopulmonary bypass despite full heparinization and adequate activated clotting time -A case report-
We reports a case of a newly formed thrombus in the left atrial appendage during cardiopulmonary bypass detected by transesophageal echocardiography in a patient with chronic atrial fibrillation and mitral stenosis. This case alerts the anesthesiologists of possible thrombus formation despite full heparinization during cardiac surgery and the importance of a comprehensive echocardiography exami...
متن کاملA dynamic bubble trap reduces microbubbles during cardiopulmonary bypass: a case study.
Microemboli passing to the cerebral circulation during cardiopulmonary bypass can contribute to postoperative neurologic dysfunction. Many studies conclude that air microbubbles predominantly are responsible for this problem. A dynamic bubble trap (DBT) was developed to diminish the number of microbubbles in the arterial line of extracorporeal circulation. The DBT is able to substantially reduc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cases Journal
دوره 1 شماره
صفحات -
تاریخ انتشار 2008