High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition
نویسندگان
چکیده
High-resolution diffusion MRI can provide the ability to resolve small brain structures, enabling investigations of detailed white matter architecture. A major challenge for in vivo high-resolution diffusion MRI is the low signal-to-noise ratio. In this work, we combine two highly compatible methods, ultra-high field and three-dimensional multi-slab acquisition to improve the SNR of high-resolution diffusion MRI. As each kz plane is encoded using a single-shot echo planar readout, scan speeds of the proposed technique are similar to the commonly used two-dimensional diffusion MRI. In-plane parallel acceleration is applied to reduce image distortions. To reduce the sensitivity of auto-calibration signal data to subject motion and respiration, several new adaptions of the fast low angle excitation echo-planar technique (FLEET) that are suitable for 3D multi-slab echo planar imaging are proposed and evaluated. A modified reconstruction scheme is proposed for auto-calibration with the most robust method, Slice-FLEET acquisition, to make it compatible with navigator correction of motion induced phase errors. Slab boundary artefacts are corrected using the nonlinear slab profile encoding method recently proposed by our group. In vivo results demonstrate that using 7T and three-dimensional multi-slab acquisition with improved auto-calibration signal acquisition and nonlinear slab boundary artefacts correction, high-quality diffusion MRI data with ~1mm isotropic resolution can be achieved.
منابع مشابه
High Resolution 3D Multi-slab Multi-shot Spin Echo Diffusion-Weighted Imaging
Introduction: The need to detect small brain lesions and to reduce partial volume effects in fiber tractography has made high resolution isotropic 3D diffusion-weighted imaging (DWI) a research focus in diffusion acquisition methodology [1-4]. To achieve reasonable scan time, most of the proposed 3D DWI methods used steady-state free precession (SSFP) acquisition [1-3] which has a complicated d...
متن کاملHigh Resolution Diffusion Tensor Imaging of the Human Brain at 7T
Magnetic resonance imaging (MRI) at 7T provides higher signal-to-noise ratio (SNR) which enables high-resolution functional and anatomic MRI. There is also an increased demand for high-resolution diffusion tensor imaging (DTI) providing important information about cell physiology and neuronal connectivity. DTI may also profit from higher SNR as diffusion-weighting reduces the signal exponential...
متن کاملDiffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.
Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...
متن کاملHigh resolution MR imaging and spectroscopy of the human breast at 7T using a focused field RF coil setup
Introduction Contrast enhanced breast MRI has clinical relevance in cancer diagnoses and treatment monitoring, however at a limited specificity. Functional MRI techniques, like diffusion MRI and MR spectroscopy will contribute to improved specificity but compromised in sensitivity due to low spatial resolution. At 1.5T or 3T the improve of spatial is hindered by low signal to noise ratios even ...
متن کاملHigh Resolution Cerebral Blood Volume Mapping in Humans at 7T with Hyperoxic Contrast
Introduction Increasing the inspired fraction of oxygen (FiO2>0.21) has been shown to produce positive contrast enhancement in T2-weighted images based on the blood oxygenation-dependent (BOLD) effect [1]. Recently, it has been shown that cerebral blood volume (CBV) can be accurately calculated by measuring signal changes in echo-planar images (EPI) at 3T during short epochs (<6min) of mild hyp...
متن کامل