A palmtop-sized rotary-drive-type biochemical analysis system by magnetic bead handling
نویسندگان
چکیده
Abstract By applying a single rotary motion to our previously developed magnetic bead droplet handling mechanism, we recently developed transportation and agitation operation mechanisms aiming at realizing a portable-sized biochemical analysis system. We used two permanent magnets for transporting beads and another magnet coupled with multi-layered flat coils for agitation. They are all mounted on a rotational table, and the total size of the system is 60 × 45 × 35 mm3. We experimentally confirmed that the developed system can do all the bead handlings (transportation, extraction, fusion and agitation) by rotational motion only.
منابع مشابه
Magnetic bead handling on-chip: new opportunities for analytical applications
This review describes recent advances in the handling and manipulation of magnetic particles in microfluidic systems. Starting from the properties of magnetic nanoparticles and microparticles, their use in magnetic separation, immuno-assays, magnetic resonance imaging, drug delivery, and hyperthermia is discussed. We then focus on new developments in magnetic manipulation, separation, transport...
متن کاملConvectional hydrothermal synthesis of high-purity pesudo-cubic BaTi0.09Nb0.01O3 nanocrystals in rotary autoclave
Nano-sized BaTiO3 powders with particular Nb concentrations were prepared by Rotary- Hydrothermal (RH) method. Hydrothermal method was used at 180 °C for 5 hours with new Ti pressure and the teflon vessel was rotated at a speed of 160 rpm during the hydrothermal reaction. New hydrothermal method was used instead of previous solid state reaction for the system BaTiO3±Nb<sub...
متن کاملConvectional hydrothermal synthesis of high-purity pesudo-cubic BaTi0.09Nb0.01O3 nanocrystals in rotary autoclave
Nano-sized BaTiO3 powders with particular Nb concentrations were prepared by Rotary- Hydrothermal (RH) method. Hydrothermal method was used at 180 °C for 5 hours with new Ti pressure and the teflon vessel was rotated at a speed of 160 rpm during the hydrothermal reaction. New hydrothermal method was used instead of previous solid state reaction for the system BaTiO3±Nb<sub...
متن کاملStability Analysis of a Matrix Converter Drive: Effects of Input Filter Type and the Voltage Fed to the Modulation Algorithm
The matrix converter instability can cause a substantial distortion in the input currents and voltages which leads to the malfunction of the converter. This paper deals with the effects of input filter type, grid inductance, voltage fed to the modulation algorithm and the synchronous rotating digital filter time constant on the stability and performance of the matrix converter. The studies are ...
متن کاملFully Integrated Rotary Genetic Analysis System
In this study, a fully integrated and portable Rotary Genetic Analyzer has been developed to analyze the gene expression of influenza A v irus . The Rotary Genetic Analyzer is made up of four parts : a disposable microchip, three thermal blocks for temperature control, a servo-motor for precise and high-rate spinning of the chip, and a miniaturized optical fluorescence detector. The microdevice...
متن کامل