How useful are the "other" semipermeable membrane devices (SPMDs); the mini-unit (15.2 cm long)?

نویسندگان

  • Steven L Goodbred
  • Wade L Bryant
  • Michael R Rosen
  • David Alvarez
  • Terri Spencer
چکیده

Mini (15.2 cm) semipermeable membrane devices (SPMDs) were used successfully in 169 streams from six metropolitan areas of the US to sequester hydrophobic organic compounds (HOCs) that are indicative of urbanization. A microscale assay the P450RGS, which responds to compounds that bind to the aryl hydrocarbon receptor (AhR), and the Fluoroscan, a chemical screen for polycyclic aromatic hydrocarbons (PAHs), were performed on each mini SPMD extract. Results show both tests were sensitive enough to respond in streams with low urbanization and responded exponentially in a predictable way to a gradient of urbanization. Mini SPMDs had sufficient sampling rates to detect HOCs using gas chromatography with mass spectrometric detection (GC/MS) in streams with low levels of urbanization. The total number of HOCs in streams had a linear response to a gradient of urbanization, where 73 of 140 targeted compounds were detected. A diverse group of compounds was found in urban streams including, PAHs, insecticides, herbicides, musk fragrances, waste water treatment compounds and flame retardants. Pentachloroanisole (PCA), a breakdown product of pentachlorophenol (wood preservative), was the most ubiquitous HOC, and was detected in 71% of streams. An evaluation of mini SPMD performance showed they can detect concentrations in water below toxicity benchmarks for many HOCs with the exception of 2,3,7,8 tetrachlorodibenzo-p-dioxin. A comparison of mini SPMDs with full sized (91.4 cm) SPMDs showed they have several distinct advantages. The most notable advantages are their low cost, small size, and reduced chance of vandalism. The greatest limitation is the inability to detect compounds at low concentrations (pg/L). Mini SPMDs perform quite well in a wide array of environmental settings and applications and should be considered as an option in environmental studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Further developments in the use of semipermeable membrane devices (SPMDs) as passive air samplers for persistent organic pollutants: field application in a spatial survey of PCDD/Fs and PAHs.

Semipermeable membrane devices (SPMDs) were deployed at 19 sites in northwest England to test their efficacy as passive atmospheric samplers for polychlorinated dibenzo-p-dioxins and -furans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs). SPMDs were found to be efficient samplers for vapor phase species in the atmosphere, with good reproducibility between samplers. Species which are part...

متن کامل

Performance of semipermeable membrane devices for sampling of organic contaminants in groundwater.

Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for moni...

متن کامل

Use of triolein-semipermeable membrane devices to assess the bioconcentration and sediment sorption of hydrophobic organic contaminants in the Huaihe River, China.

Triolein-containing semipermeable membrane devices (triolein-SPMD) were deployed I m above the sediments at two sampling sites in the Huaihe River, China, for a period of 28 d. Sediment and fish samples were simultaneously collected from the same sampling sites. Concentrations of substituted benzenes, selected pesticides, polycyclic aromatic hydrocarbon (PAH), and polychlorinated biphenyls (PCB...

متن کامل

Field uptake rates of hydrophobic organic contaminants by semipermeable membrane devices: environmental monitoring considerations.

The uptake rates of selected hydrophobic organic contaminants (HOCs) by semipermeable membrane devices (SPMDs)--a polyethylene layflat containing the lipid triolein--were investigated under natural conditions. SPMDs were exposed in three sampling sites (industrial, urban, and agricultural areas) in the Tajo River (Toledo, Spain) for 5, 11 and 20 d. The organochlorine compounds 4,4'-DDT, 4,4'-DD...

متن کامل

Detection of persistent organic pollutants in the Mississippi Delta using semipermeable membrane devices.

From semipermeable membrane devices (SPMDs) placed in five Mississippi Delta streams in 1996 and 1997, the persistent organic pollutants (POPs) aldrin, chlordane, DCPA, DDT, dieldrin, endrin, heptachlor, mirex, nonachlor, and toxaphene were detected. In addition, the insecticides chlorpyriphos, endosulfan, and hexachlorocyclohexanes were detected. Two low-solubility herbicides not detected comm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 407 13  شماره 

صفحات  -