PURPOSE The purpose of this study was to characterize aberrations in 2 populations of eyes, namely those with keratoconus (KC) and those having undergone penetrating keratoplasty (PK), using a large-dynamic range Shack-Hartmann wavefront sensor. DESIGN Prospective comparative case series. PARTICIPANTS Twenty-one people with ocular pathologic features (either KC or PK) were recruited for this study. A previously compiled population of 190 people with no pathologic features other than refractive error was used as a means for comparison. METHODS Thirty-three abnormal eyes (19 with KC and 14 PK) were measured using a high-dynamic range wavefront sensor, and Zernike coefficients were computed over a 6-mm pupil. The data then were used to characterize the populations by themselves, as well as to compare them with the population of normal eyes. MAIN OUTCOME MEASURES Root mean square (RMS) higher-order aberration (HOA), percent of higher-order or total aberration variance, and magnitude of individual Zernike modes (in micrometers). Visual benefit of correcting higher-order aberrations was used when comparing pathologic and normal populations. RESULTS The keratoconic eyes exhibited 2.24 microm of HOA RMS on average. Vertical coma accounted for 53+/-32% (mean+/-standard deviation [SD]) of the HOA variance and was the most dominant higher-order aberration. The PK subjects had an average higher-order RMS of 2.25 microm, and trefoil dominated in this population with an average HOA variance contribution of 38+/-23% (mean+/-SD). The KC and PK higher-order aberrations represented 16+/-20% and 16+/-13% (mean+/-SD) of the total aberration variance, whereas the ratio was only 1+/-1% in the normal population. A visual benefit calculation on 15 KC eyes and 14 PK eyes yielded a result of 4.4+/-2.0 and 6.0+/-1.5 (mean+/-SD), respectively, whereas the normal population had a visual benefit of only 2.1+/-0.4. CONCLUSIONS Eyes with KC and PK have higher-order aberrations that are approximately 5.5 times more than what is typical in normal eyes. Vertical coma is the dominant higher-order aberration in people with KC, whereas PK eyes are dominated by trefoil, spherical aberration, and coma. Correcting these aberrations may provide substantial improvements in vision beyond what is possible with conventional correction methods.
منابع مشابه
Predicting visual performance from optical quality metrics in keratoconus.
PURPOSE The aim was to identify optical quality metrics predictive of visual performance in eyes with keratoconus and penetrating keratoplasty (PK) for keratoconus. METHODS Fifty-four participants were recruited for this prospective, cross-sectional study. Data were collected from one eye of each participant: 26 keratoconus, 10 PK and 18 normal eyes: average age (mean +/- standard deviation) ...
متن کاملComparison of Zernike and Fourier wavefront reconstruction algorithms in representing the corneal aberration of normal and abnormal eyes
Purpose: The goal of this study was to investigate with what accuracy the Zernike and Fourier reconstruction algorithms can describe the corneal aberration in normal and abnormal eyes. Methods: Corneal topography (Orbscan IIz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 post-LASIK symptomatic eyes. Raw topography images were converted into elevation maps...
متن کاملRisk Factors for Failure of Keratoplasty in Keratoconus: Penetrating vs. Deep Anterior Lamellar Keratoplasty
Purpose: To determine the etiologic factors on rejection and failure rates and ocular surface changes after corneal transplantation by either DALK or PKP, in cases of keratoconus (KCN). Methods: In this cross-sectional study, considering the existing data, patients with keratoconus referring to Labbafinejad Medical Center from 2006 to 2016, who underwent corneal transplantation, were enrolled a...
متن کاملGeneration of Higher Order Aberrations with Soft Contact Lens by Excimer Laser Ablation
Although the human eye has a relatively simple optical system, it is not perfect. It has been well known that the human eye suffers from the wavefront aberration that includes both lower (defocus and astigmatism) and higher order aberrations. The lower order aberration has been effectively corrected with conventional ophthalmic lenses such as spectacles and contact lenses. However, it is more c...
متن کاملComparison of Zernike and Fourier wavefront reconstruction algorithms in representing corneal aberration of normal and abnormal eyes.
PURPOSE To investigate the accuracy of Zernike and Fourier reconstruction algorithms in describing simulated wavefront data from corneal topography of normal and abnormal eyes. METHODS Corneal topography (Orbscan Ilz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 postoperative LASIK symptomatic eyes over a 6-mm pupil. Raw data from slit images were conve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmology
دوره 114 11 شماره
صفحات -
تاریخ انتشار 2007