Thick Film Resistors Ndt by Electro-ultrasonic Spectroscopy
نویسندگان
چکیده
The non-linear electro-ultrasonic spectroscopy was used as a non-destructive testing method for the polymer based and cermet thick film resistors evaluation. We carried out the correlation between this method and standard testing methods as noise spectroscopy and the third harmonic voltage measurements. The measuring set-up with the ultrasonic transducer working on the frequency range 10 kHz to 1 MHz was designed and realized. Proposed method is exploiting two different signal sources – ultrasonic wave and alternating electric current. Mechanical vibrations affect the defects in the sample structure and it influences the electric charge transport through the measured structure. Resulting information is measured on the differential frequency given by the superposition or subtraction of exciting signals frequencies. Low-pass filter with limit frequency 5 kHz was used for the suppression of exciting signals amplitudes. Measured sample together with the ultrasonic transducer creates the resonant system. For the thick film resistor samples prepared on the alumina substrate we achieved high sensitivity measuring on the resonant frequencies determined by the alumina substrate size. Four-point method was used for the elimination of the contact influence on the measured characteristics. The intermodulation signal was measured on the frequency in the range 2 to 5 kHz. The intermodulation signal amplitude increases linearly with the amplitude of alternating electric current, and with the square of increasing voltage on the ultrasonic transducer. The intermodulation signal amplitude is further influenced by the sample technology. The intermodulation voltage is influenced by the AC current value and on the resistance change of contacts among the conducting grains in the thick film resistor structure. Ultrasonic signal changes the area of the contact between the conducting grains in the resistor structure, hence the square-law between the voltage on the ultrasonic transducer and the intermodulation voltage is observed. The method sensitivity is influenced by the measuring set-up noise background. The intermodulation signal amplitude was measured to be about one order above the measuring set-up background noise voltage for the current 1 mA flowing through the structure. In this case no sample heating is observed even for through the long term measurements. The relative resistance change is of the order of 10 for the polymer based thick film resistors, and of the order of 10 for the cermet samples. There is a correlation between the resistance value and the intermodulation voltage. At the same time there exists the correlation between the amplitude of intermodulation voltage and the value of the noise spectral density or the value of the third harmonic signal amplitude, respectively. It happens in all cases that with the increasing number of contacts among the conducting grains in the sample there are decreasing the amplitude of intermodulation voltage, as well as the value of the noise spectral density, the value of the third harmonic signal amplitude, and the resistance for the samples with identical geometry. This enables to evaluate the sample technology.
منابع مشابه
Effects of High Voltage Pulse Trimming on Structural Properties of Thick-Film Resistors
Nowadays, compact and reliable electronic devices including up-to-date ceramic micro-electro-mechanical systems require thick-film resistors with significantly reduced dimensions and stable and precise resistance values. For that reason, instead of standard laser trimming method, high voltage pulse trimming of thick-film resistors is being introduced. This method allows controlled and reliable ...
متن کاملNoise properties of thick-film resistors in extended temperature range
Results of thorough experimental studies on electrical properties of thick-film resistors (TFRs) have been overviewed and summarized. Experiments covered resistance and noise measurements in wide temperature range. Low-frequency noise spectroscopy has been used for the investigations of fluctuating phenomena. Sample resistors were prepared of various combinations of commercial and laboratory-ma...
متن کاملAdvanced Electro-thermal Modeling for Surface Mount Resistors
Exceeding component maximum ratings due to transient events like current spikes can lead to premature failure of surface mount resistors due to thermal and electrical overstress. In order to accurately evaluate device parameters and their impact on the circuit behavior a coupled electro-thermal simulation method must be applied under the influence of packaging. This article presents an analysis...
متن کاملMeasurement of 1/f Noise in Carbon Composition and Thick Film Resistors
Thermal noise and 1/f noise are known to exist in carbon composition (CC) and thick film (TF) resistors. A circuit involving a differential instrumentation op-amp was used to measure the noise of a resistor under test. The noise spectra of these resistors were measured using a dynamic signal analyzer that performs an auto-correlation Fourier transform from the time domain to the frequency domai...
متن کاملEvaluation of conductive-to-resistive layers interaction in thick-film resistors
Low-frequency noise spectroscopy is used to examine the interactions between resistive and conductive films that take place during thick-film resistor (TFR) fabrication. Two noise parameters are introduced to quantitatively describe the strength of these interactions. They refer to intensity and repeatability of the noise generated in the resistor interfaces. Extensive experimental studies perf...