Effect of vibration on the shear strength of impacted bone graft in revision hip surgery.
نویسندگان
چکیده
We developed a method of applying vibration to the impaction bone grafting process and assessed its effect on the mechanical properties of the impacted graft. Washed morsellised bovine femoral heads were impacted into shear test rings. A range of frequencies of vibration was tested, as measured using an accelerometer housed in a vibration chamber. Each shear test was repeated at four different normal loads to generate stress-strain curves. The Mohr-Coulomb failure envelope from which shear strength and interlocking values are derived was plotted for each test. The experiments were repeated with the addition of blood in order to replicate a saturated environment. Graft impacted with the addition of vibration at all frequencies showed improved shear strength when compared with impaction without vibration, with 60 Hz giving the largest effect. Under saturated conditions the addition of vibration was detrimental to the shear strength of the aggregate. The civil-engineering principles of particulate settlement and interlocking also apply to impaction bone grafting. Although previous studies have shown that vibration may be beneficial in impaction bone grafting on the femoral side, our study suggests that the same is not true in acetabular revision.
منابع مشابه
Anterior Cruciate Ligament Reconstruction with Hamstring Tendons Has no Deleterious Effect on Hip Extension Strength
Background: Hamstring tendons are secondary hip extensors. Their harvest for graft in anterior cruciate ligament(ACL) reconstruction may create deleterious effect on hip extension strength. This is of particular importance in sportsthat need powerful hip extension force like climbing and sprinting. Due to scarcity of a comprehensive study in thisarea, we designed this prospect...
متن کاملMechanical characteristics of the bone-graft-cement interface after impaction allografting.
Impaction allografting is an attractive procedure for the treatment of failed total hip replacements. The graft-cement-host bone interface after impaction allografting has not been characterized, although it is a potential site of subsidence for this type of revision total hip reconstruction. In six human cadaveric femurs, the cancellous bone was removed proximally and local diaphyseal lytic de...
متن کاملVibration-assisted bone-graft compaction in impaction bone grafting of the femur.
The complications of impaction bone grafting in revision hip replacement includes fracture of the femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and...
متن کاملRinsing of allograft bone does not improve implant fixation
BACKGROUND AND PURPOSE Impacted morselized allograft bone is a well-established method for reconstructing bone defects at revision surgery. However, the incorporation of bone graft is not always complete, and a substantial volume of fibrous tissue has been found around grafted implants. We hypothesized that rinsing the bone graft may improve graft incorporation by removing the majority of immun...
متن کاملIrradiation Does Not Influence Incorporation of Impacted Morselized Bone
Introduction: In revision surgery bone defects can be filled with impacted bone grafts. The use of graft material carries a potential but well established risk of disease transmission. Gamma irradiation of the graft material is getting more popular for prevention of disease transmission. Due to changes in mechanical properties of bone by gamma irradiation, it has been used with some cautiousnes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 93 6 شماره
صفحات -
تاریخ انتشار 2011