Turbulent Kinetic Energy Assessed by Multipoint 4-Dimensional Flow Magnetic Resonance Imaging Provides Additional Information Relative to Echocardiography for the Determination of Aortic Stenosis Severity.

نویسندگان

  • Christian Binter
  • Alexander Gotschy
  • Simon H Sündermann
  • Michelle Frank
  • Felix C Tanner
  • Thomas F Lüscher
  • Robert Manka
  • Sebastian Kozerke
چکیده

BACKGROUND Turbulent kinetic energy (TKE), assessed by 4-dimensional (4D) flow magnetic resonance imaging, is a measure of energy loss in disturbed flow as it occurs, for instance, in aortic stenosis (AS). This work investigates the additional information provided by quantifying TKE for the assessment of AS severity in comparison to clinical echocardiographic measures. METHODS AND RESULTS Fifty-one patients with AS (67±15 years, 20 female) and 10 healthy age-matched controls (69±5 years, 5 female) were prospectively enrolled to undergo multipoint 4D flow magnetic resonance imaging. Patients were split into 2 groups (severe and mild/moderate AS) according to their echocardiographic mean pressure gradient. TKE values were integrated over the aortic arch to obtain peak TKE. Integrating over systole yielded total TKEsys and by normalizing for stroke volume, normalized TKEsys was obtained. Mean pressure gradient and TKE correlated only weakly (R2=0.26 for peak TKE and R2=0.32 for normalized TKEsys) in the entire study population including control subjects, while no significant correlation was observed in the AS patient group. In the patient population with dilated ascending aorta, both peak TKE and total TKEsys were significantly elevated (P<0.01), whereas mean pressure gradient was significantly lower (P<0.05). Patients with bicuspid aortic valves also showed significantly increased TKE metrics (P<0.01), although no significant difference was found for mean pressure gradient. CONCLUSIONS Elevated TKE levels imply higher energy losses associated with bicuspid aortic valves and dilated ascending aortic geometries that are not assessable by current echocardiographic measures. These findings indicate that TKE may provide complementary information to echocardiography, helping to distinguish within the heterogeneous population of patients with moderate to severe AS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance measurement of turbulent kinetic energy for the estimation of irreversible pressure loss in aortic stenosis.

OBJECTIVES The authors sought to measure the turbulent kinetic energy (TKE) in the ascending aorta of patients with aortic stenosis and to assess its relationship to irreversible pressure loss. BACKGROUND Irreversible pressure loss caused by energy dissipation in post-stenotic flow is an important determinant of the hemodynamic significance of aortic stenosis. The simplified Bernoulli equatio...

متن کامل

Turbulent Kinetic Energy Measurement Using Phase Contrast MRI for Estimating the Post-Stenotic Pressure Drop: In Vitro Validation and Clinical Application

BACKGROUND Although the measurement of turbulence kinetic energy (TKE) by using magnetic resonance imaging (MRI) has been introduced as an alternative index for quantifying energy loss through the cardiac valve, experimental verification and clinical application of this parameter are still required. OBJECTIVES The goal of this study is to verify MRI measurements of TKE by using a phantom sten...

متن کامل

Assessment of Aortic Stenosis Severity by Cardiovascular Magnetic Resonance

Cardiovascular magnetic resonance (CMR) has become a valuable tool to corroborate aortic stenosis (AS) severity when echocardiography assessment is discordant. Moreover, CMR can provide useful complementary information about AS severity and hemodynamic markers. In particular, the use of advanced 4D flow CMR allows a comprehensive assessment of complex flow alterations produced by AS. This revie...

متن کامل

Turbulent kinetic energy in the ascending aorta is greater in bicuspid than tricuspid aortic valve stenosis

Background The main determinant of the haemodynamic significance of aortic stenosis (AS) is the irreversible pressure loss that is created by the stenosis. The majority of the pressure loss is caused by conversion/dissipation of turbulent kinetic energy (TKE) to heat. Recent developments in cardiac magnetic resonance 4D flow imaging have allowed the noninvasive assessment of TKE. Bicuspid aorti...

متن کامل

Assessment of energy loss in aortic stenosis using Bayesian multipoint phase-contrast MRI

Background Aortic stenosis is the most prevalent valvular heart disease. The current gold standard for determination of the disease severity is Doppler echocardiography, but the decision for valve replacement is mostly based on the patient experiencing symptoms [1]. Doppler echocardiography measures the velocity across the valve, which is only indirectly linked to the energy loss associated wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2017