Methods are developed for the design of electrical impedance tomographic reconstruction algorithms with specified properties. Assuming a starting model with constant conductivity or some other specified background distribution, an algorithm with the following properties is found. (1) The optimum constant for the starting model is determined automatically. (2) The weighted least-squares error between the predicted and measured power dissipation data is as small as possible. (3) The variance of the reconstructed conductivity from the starting model is minimized. (4) Potential distributions with the largest volume integral of gradient squared have the least influence on the reconstructed conductivity, and therefore distributions most likely to be corrupted by contact impedance effects are deemphasized. (5) Cells that dissipate the most power during the current injection tests tend to deviate least from the background value. For a starting model with nonconstant conductivity, the reconstruction algorithm has analogous properties.
منابع مشابه
Inverse method for imaging a free surface using electrical impedance tomography
The feasibility of inverting measurements from electrical impedance tomography (EIT) to image the free surface of a homogeneous conductor within an open channel is investigated. Potential measurements from a linear array of electrodes placed at the bottom of the channel are simulated using a "nite element method. The simulated measurements are inverted using an iterative, sometimes weighted, le...
متن کاملFine-tuning Electrode Information in Electrical Impedance Tomography
Electrical impedance tomography is a noninvasive imaging technique for recovering the admittivity distribution inside a body from boundary measurements of current and voltage. In practice, impedance tomography suffers from inaccurate modelling of the measurement setting: The exact electrode locations and the shape of the imaged object are not necessarily known precisely. In this work, we tackle...
متن کاملRecovering from an Inaccurately Known Measurement Configuration via Polynomial Collocation in Electrical Impedance Tomography
The objective of electrical impedance tomography is to reconstruct the internal conductivity of a physical body based on measurements of current and potential at a finite number of electrodes attached to its boundary. Although the conductivity is the quantity of main interest in impedance tomography, a real-world measurement configuration includes other unknown parameters as well: the informati...
متن کاملResolution and Stability Analysis of an Inverse Problem in Electrical Impedance Tomography: Dependence on the Input Current Patterns
Electrical impedance tomography is a procedure by which one nds the conductivity distribution inside a domain from measurements of voltages and currents at the boundary. This work addresses the issue of stability and resolution limit of such an imaging device. We consider the realistic case where only a nite number of measurements are available. An important feature of our approach, which is ba...
متن کاملModified Weighted Least Squares Method to Improve Active Distribution System State Estimation
The development of communications and telecommunications infrastructure, followed by the extension of a new generation of smart distribution grids, has brought real-time control of distribution systems to electrical industry professionals’ attention. Also, the increasing use of distributed generation (DG) resources and the need for participation in the system voltage control, which is possible ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on medical imaging
دوره 11 2 شماره
صفحات -
تاریخ انتشار 1992