Evaluation of optimum room entry times for radiation therapists after high energy whole pelvic photon treatments.

نویسندگان

  • Lavine Ho
  • Peter White
  • Edward Chan
  • Kim Chan
  • Janet Ng
  • Timothy Tam
چکیده

OBJECTIVES Linear accelerators operating at or above 10 MV produce neutrons by photonuclear reactions and induce activation in machine components, which are a source of potential exposure for radiation therapists. This study estimated gamma dose contributions to radiation therapists during high energy, whole pelvic, photon beam treatments and determined the optimum room entry times, in terms of safety of radiation therapists. METHODS Two types of technique (anterior-posterior opposing and 3-field technique) were studied. An Elekta Precise treatment system, operating up to 18 MV, was investigated. Measurements with an area monitoring device (a Mini 900R radiation monitor) were performed, to calculate gamma dose rates around the radiotherapy facility. Measurements inside the treatment room were performed when the linear accelerator was in use. The doses received by radiation therapists were estimated, and optimum room entry times were determined. RESULTS The highest gamma dose rates were approximately 7 μSv/h inside the treatment room, while the doses in the control room were close to background (~0 μSv/h) for all techniques. The highest personal dose received by radiation therapists was estimated at 5 mSv/yr. To optimize protection, radiation therapists should wait for up to11 min after beam-off prior to room entry. CONCLUSIONS The potential risks to radiation therapists with standard safety procedures were well below internationally recommended values, but risks could be further decreased by delaying room entry times. Dependent on the technique used, optimum entry times ranged between 7 to 11 min. A balance between moderate treatment times versus reduction in measured equivalent doses should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of room entry times for radiation therapists after routine 15 MV photon treatments

Background: Radiation therapy  uses high-energy radiation to kill cancer cells. Photoneutron contamination and induced radioactivity of high energy therapeutic photon beams are considered as the main source of occupational exposure to radiation therapists who works with linear accelerators operating above 10 MV. Materials and Methods: The gamma dose rates were measured after termination of...

متن کامل

Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

متن کامل

Evaluation of Iridium_192 radioisotope dosimeter calculations for vascular Brachiotherapy

Introduction: One of the most effective means for treatment of coronary arteries cramp (CHD) is coronary intravascular Brachiotherapy. In this study, with use of MCNP code, in order to invastigating the score of ditribution of absorbed dose, drope in dose, and simulation mean, radiation doses around iridium_192 radioactive has been done.   Materials and Methods:</str...

متن کامل

The evaluation of change in attenuation coefficient of cerrobend block used for radiation protection of healthy tissues in megavoltage photon radiation therapy after multiple melting

Introduction: Protecting the vital organs in radiation therapy is one of the most important issues. Cerrobend alloy, the most common material used as the shield, is melted several times and used for different patients. In this study changes in attenuation coefficient of cerrobend due to melting was investigated.   Materials and Methods: In melting furnace, ...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational health

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2012